Literature DB >> 18539286

A new technique to measure the dynamic contact pressures on the Tibial Plateau.

Jocelyn M Cottrell1, Paul Scholten, Tony Wanich, Russell F Warren, Timothy M Wright, Suzanne A Maher.   

Abstract

Studies of the load transfer role of the meniscus have been limited to static experimental and analytical approaches. The objective of this study was to develop an experimental technique to allow the contact pressures on the tibial plateau of cadaveric knees to be measured under dynamic physiological loads. Accordingly, we adapted a load-controlled knee joint simulator to accept a cadaveric sheep knee, programmed the simulator with sheep gait kinematics data, and utilized a pressure sensor array to measure the contact pressure distribution on the lateral tibial plateau during gait. The technique was applied to six sheep knees that were tested intact and after meniscectomy. Meniscectomy resulted in a 267% increase in average contact pressure, a 117% increase in peak contact pressure, and an 80% decrease in contact area, all measured at the point of maximum peak contact stress in the gait cycle. It is envisaged that the experimental model herein developed will allow for the screening of candidate materials prior to more expensive and time-consuming animal models.

Entities:  

Mesh:

Year:  2008        PMID: 18539286     DOI: 10.1016/j.jbiomech.2008.04.024

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Genipin crosslinking decreases the mechanical wear and biochemical degradation of impacted cartilage in vitro.

Authors:  Craig M Bonitsky; Megan E McGann; Michael J Selep; Timothy C Ovaert; Stephen B Trippel; Diane R Wagner
Journal:  J Orthop Res       Date:  2016-09-19       Impact factor: 3.494

2.  A Hydrogel Meniscal Replacement: Knee Joint Pressure and Distribution in an Ovine Model Compared to Native Tissue.

Authors:  Kristine M Fischenich; Hannah M Pauly; Jackson T Lewis; Travis S Bailey; Tammy L Haut Donahue
Journal:  Ann Biomed Eng       Date:  2018-06-19       Impact factor: 3.934

3.  Bone Plug Versus Suture-Only Fixation of Meniscal Grafts: Effect on Joint Contact Mechanics During Simulated Gait.

Authors:  Hongsheng Wang; Albert O Gee; Ian D Hutchinson; Kirsten Stoner; Russell F Warren; Tony O Chen; Suzanne A Maher
Journal:  Am J Sports Med       Date:  2014-04-28       Impact factor: 6.202

4.  Altered regional loading patterns on articular cartilage following meniscectomy are not fully restored by autograft meniscal transplantation.

Authors:  H Wang; T Chen; A O Gee; I D Hutchinson; K Stoner; R F Warren; S A Rodeo; S A Maher
Journal:  Osteoarthritis Cartilage       Date:  2014-12-09       Impact factor: 6.576

Review 5.  Meniscus tissue engineering on the nanoscale: from basic principles to clinical application.

Authors:  Brendon M Baker; Albert O Gee; Neil P Sheth; G Russell Huffman; Brian J Sennett; Thomas P Schaer; Robert L Mauck
Journal:  J Knee Surg       Date:  2009-01       Impact factor: 2.757

6.  Dynamic contact stress patterns on the tibial plateaus during simulated gait: a novel application of normalized cross correlation.

Authors:  Hongsheng Wang; Tony Chen; Peter Torzilli; Russell Warren; Suzanne Maher
Journal:  J Biomech       Date:  2013-12-03       Impact factor: 2.712

7.  Image based weighted center of proximity versus directly measured knee contact location during simulated gait.

Authors:  Hongsheng Wang; Tony Chen; Matthew F Koff; Ian D Hutchinson; Susannah Gilbert; Dan Choi; Russell F Warren; Scott A Rodeo; Suzanne A Maher
Journal:  J Biomech       Date:  2014-04-16       Impact factor: 2.712

8.  Changes in the loading of tibial articular cartilage following medial meniscectomy: a finite element analysis study.

Authors:  Halil Atmaca; Cevdet Cumhur Kesemenli; Kaya Memişoğlu; Arif Özkan; Yusuf Celik
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-30       Impact factor: 4.342

9.  An evaluation of meniscal collagenous structure using optical projection tomography.

Authors:  Stephen H J Andrews; Janet L Ronsky; Jerome B Rattner; Nigel G Shrive; Heather A Jamniczky
Journal:  BMC Med Imaging       Date:  2013-07-23       Impact factor: 1.930

10.  Proteoglycan 4 predicts tribological properties of repaired cartilage tissue.

Authors:  Zhiguang Qiao; Mei Xin; Ling Wang; Huiwu Li; Chengtao Wang; Liao Wang; Tingting Tang; Bangshang Zhu; Gang Huang; You Wang; Minghao Zheng; Kerong Dai
Journal:  Theranostics       Date:  2020-01-22       Impact factor: 11.556

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.