Literature DB >> 18538856

Dynamic contrast-enhanced susceptibility-weighted perfusion MRI (DSC-MRI) in a glioma model of the rat brain using a conventional receive-only surface coil with a inner diameter of 47 mm at a clinical 1.5 T scanner.

Stephan Ulmer1, Matthias Reeh, Joerg Krause, Thomas Herdegen, Janka Heldt-Feindt, Olav Jansen, Axel Rohr.   

Abstract

Magnetic resonance (MR) imaging in animal models is usually performed in expensive dedicated small bore animal scanners of limited availability. In the present study a standard clinical 1.5 T MR scanner was used for morphometric and dynamic contrast-enhanced susceptibility-weighted MR imaging (DSC-MRI) of a glioma model of the rat brain. Ten male Wistar rats were examined with coronal T2-weighted, and T1-weighted images (matrix 128 x 128, FOV 64 mm) after implantation of an intracerebral tumor xenografts (C6) using a conventional surface coil. For DSC-MRI a T2*-weighted sequence (TR/TE=30/14 ms, matrix 64 x 64, FOV 90 mm; slice thickness of 1.5mm) was performed. Regions of interest were defined within the tumor and the non-affected contralateral hemisphere and the mean transit time (MTT) was determined. Tumor dimensions in MR predicted well its real size as proven by histology. The MTT of contrast agent passing through the brain was significantly decelerated in the tumor compared to the unaffected hemisphere (p<0.001, paired t-test), which is most likely due to the leakage of contrast agent through the disrupted blood brain barrier. This setup offers advanced MR imaging of small animals without the need for dedicated animal scanners or dedicated custom-made coils.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18538856     DOI: 10.1016/j.jneumeth.2008.04.022

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

Review 1.  Whole animal imaging.

Authors:  Gurpreet Singh Sandhu; Luis Solorio; Ann-Marie Broome; Nicolas Salem; Jeff Kolthammer; Tejas Shah; Chris Flask; Jeffrey L Duerk
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2010 Jul-Aug

2.  Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice.

Authors:  Eleanor Evans; Stephen J Sawiak; Alexander O Ward; Guido Buonincontri; Robert C Hawkes; T Adrian Carpenter
Journal:  Nucl Instrum Methods Phys Res A       Date:  2014-01-11       Impact factor: 1.455

3.  Effect of photodynamic therapy combined with torasemide on the expression of matrix metalloproteinase 2 and sodium-potassium-chloride cotransporter 1 in rat peritumoral edema and glioma.

Authors:  B O Li; Chao Meng; Xufeng Zhang; Damin Cong; Xin Gao; Wanlong Gao; Donghui Ju; Shaoshan Hu
Journal:  Oncol Lett       Date:  2016-02-09       Impact factor: 2.967