L Firoozmand1, R Faria, M A Araujo, R di Nicoló, M F Huthala. 1. Faculty of Dentistry UNESP, Restorative Dentistry, Av. Eng. Francisco José Longo, 777 - Jd São Dimas, São José dos Campos 12245-000 SP, Brazil. leilyfiroozmand@hotmail.com
Abstract
OBJECTIVE: The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er:YAG (Erbium: Yttrium-Aluminum-Garnet) laser. SUBJECT AND METHODS: Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases ( degrees C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er:YAG laser (2.94 microm at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. RESULTS: The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92+/-0.80 degrees C for G1, 1.34+/-0.86 degrees C for G2, and 0.75+/-0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. CONCLUSION: Temperature response to the low and high torque handpieces seemed to be similar, however the Er:YAG laser generated a lower temperature rise.
OBJECTIVE: The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er:YAG (Erbium: Yttrium-Aluminum-Garnet) laser. SUBJECT AND METHODS: Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases ( degrees C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er:YAG laser (2.94 microm at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. RESULTS: The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92+/-0.80 degrees C for G1, 1.34+/-0.86 degrees C for G2, and 0.75+/-0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. CONCLUSION: Temperature response to the low and high torque handpieces seemed to be similar, however the Er:YAG laser generated a lower temperature rise.
Authors: Walter Raucci-Neto; Carla Raquel Dos Santos; Fabrício Augusto de Lima; Jesus Djalma Pécora; Luciano Bachmann; Regina Guenka Palma-Dibb Journal: Lasers Med Sci Date: 2014-04-23 Impact factor: 3.161