Literature DB >> 18534463

Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis.

Rajmohan Murali1, S Fiona Bonar, George Kirsh, William K Walter, William L Walter.   

Abstract

The most common cause of long-term failure of total hip arthroplasty is osteolysis and aseptic loosening secondary to wear debris. Combinations of hard materials such as ceramic-on-ceramic generate smaller volumes of particulate wear debris than traditional combinations such as metal-on-polyethylene. We describe 2 cases where osteolysis arose in hips with third-generation alumina ceramic-on-ceramic couplings. Periarticular tissue in both cases contained titanium wear debris due to impingement of the neck of the titanium femoral component against the rim of the titanium shell and ceramic debris from edge loading wear (stripe wear) of the ceramic. It is not clear whether the titanium debris, the ceramic debris, or both caused the osteolysis. These cases illustrate that the risk of osteolysis persists, even with third-generation alumina ceramics.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534463     DOI: 10.1016/j.arth.2007.10.020

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Squeaking hips.

Authors:  William L Walter; Tim S Waters; Mark Gillies; Shane Donohoo; Steven M Kurtz; Amar S Ranawat; William J Hozack; Michael A Tuke
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

2.  In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report.

Authors:  Michel P Laurent; Robin Pourzal; Alfons Fischer; Kim C Bertin; Joshua J Jacobs; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-04-06       Impact factor: 5.284

3.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

4.  Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

Review 5.  How have new bearing surfaces altered the local biological reactions to byproducts of wear and modularity?

Authors:  Thomas W Bauer; Patricia A Campbell; Gretchen Hallerberg
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

6.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

Review 7.  Importance of preclinical evaluation of wear in hip implant designs using simulator machines.

Authors:  Rafael Mello Trommer; Márcia Marie Maru
Journal:  Rev Bras Ortop       Date:  2016-12-30

8.  Experimental Investigation of Material Transfer on Bearings for Total Hip Arthroplasty-A Retrieval Study on Ceramic and Metallic Femoral Heads.

Authors:  Jessica Hembus; Lisa Rößler; Armin Springer; Marcus Frank; Annett Klinder; Rainer Bader; Carmen Zietz; Andreas Enz
Journal:  J Clin Med       Date:  2022-07-07       Impact factor: 4.964

9.  Progressive Osteolysis with Hematoma Following Revision Total Hip Arthroplasty using Hydroxyapatite Mesh: A Case Report.

Authors:  Shougo Matsuda; Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  J Orthop Case Rep       Date:  2018 Jul-Aug
  9 in total