Literature DB >> 18534413

Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty.

Jose Rafael E Resubal1, David A F Morgan.   

Abstract

To compare the effectiveness of computer-assisted surgery (CAS) and mechanical jig technique in hip resurfacing arthroplasty, we reviewed 176 hip resurfacing arthroplasty performed in 158 patients. The initial 131 hips were resurfaced using the conventional mechanical jig technique, and the remaining 45 hips with the CAS technique. The demographic data of the patients were similar for both techniques. Follow-up radiographs taken 2 months after the surgery showed patients in the CAS technique having a significantly better alignment of the femoral component on the frontal and sagittal planes. There was no difference in the risk of implant notching on the femoral neck for both techniques. The implant sizes were similar for both techniques; thus, the amount of bone stock preserved was not technique specific.

Entities:  

Mesh:

Year:  2008        PMID: 18534413     DOI: 10.1016/j.arth.2007.12.013

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  [Imageless computer navigation of hip resurfacing arthroplasty].

Authors:  Christoph Schnurr; Jochen Nessler; Jürgen Koebke; Joern William Michael; Peer Eysel; Dietmar Pierre König
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

2.  Intraoperative radiographs for placing acetabular components in hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu; Lee Webb
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Avoiding short-term femoral neck fracture with imageless computer navigation for hip resurfacing.

Authors:  Michael Olsen; Emil H Schemitsch
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  A custom-made guide-wire positioning device for hip surface replacement arthroplasty: description and first results.

Authors:  Martijn Raaijmaakers; Frederik Gelaude; Karla De Smedt; Tim Clijmans; Jeroen Dille; Michiel Mulier
Journal:  BMC Musculoskelet Disord       Date:  2010-07-14       Impact factor: 2.362

5.  The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial.

Authors:  Maik Stiehler; Jens Goronzy; Albrecht Hartmann; Frank Krummenauer; Klaus-Peter Günther
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

6.  CUSTOMIZED GUIDE FOR FEMORAL COMPONENT POSITIONING IN HIP RESURFACING ARTHROPLASTY.

Authors:  Chaturong Pornrattanamaneewong; Rapeepat Narkbunnam; Keerati Chareancholvanich
Journal:  Acta Ortop Bras       Date:  2017 Mar-Apr       Impact factor: 0.513

7.  Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing--a preclinical study.

Authors:  Maik Stiehler; Jens Goronzy; Stephan Kirschner; Albrecht Hartmann; Torsten Schäfer; Klaus-Peter Günther
Journal:  Eur J Med Res       Date:  2015-02-24       Impact factor: 2.175

8.  Computer navigation experience in hip resurfacing improves femoral component alignment using a conventional jig.

Authors:  Zachary Morison; Akshay Mehra; Michael Olsen; Michael Donnelly; Emil Schemitsch
Journal:  Indian J Orthop       Date:  2013-11       Impact factor: 1.251

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.