Literature DB >> 18533161

CFD analysis of pulsatile blood flow in an atherosclerotic human artery with eccentric plaques.

Giulio Lorenzini1, Erminio Casalena.   

Abstract

Atherosclerosis is a slow vascular degeneration. It thickens the internal walls of a blood vessel locally depositing an atherosclerotic plaque. Such reduced lumen increases the resistance to blood flow. Plaques can be punctual (eccentric, here considered) or circumferential (symmetrical). Stenoses do not have a typical shape: we hypothesised here a reference geometry (trapezium) with its possible evolutions (semi-ellipse, triangle). Two criteria (Equivalent Area and Equivalent Dimensions) were then defined to compare the results among the 35 case studies numerically analysed with a Computational Fluid Dynamics code (Comsol Multiphysics 3.3). Blood was considered a Cassonian fluid with modified viscosity equation. The artery was cylindrical, rigid and straight, interested by a pulsatile blood flow. Among the variables: shape and dimensions of the stenoses; number of stenoses (single or coupled pathologies); mutual locations (3 possibilities). The main results were that the length of the consequent flow disturbance is due to the stenotic shape and height; blood flow recirculation, downstream of the pathology, is due to the slope of the stenotic walls; and the peak velocities depend on the shape and height of stenosis. The differences from case to case diminish in diastole.

Entities:  

Mesh:

Year:  2008        PMID: 18533161     DOI: 10.1016/j.jbiomech.2008.04.009

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Effect of stenosis shape on the sound emitted from a constricted blood vessel.

Authors:  Kamil Ozden; Cuneyt Sert; Yigit Yazicioglu
Journal:  Med Biol Eng Comput       Date:  2020-01-14       Impact factor: 2.602

2.  Modeling, Simulation and Validation of Alteration in Blood Flow and Regional Oxygenation Under Arterial Occlusion.

Authors:  Dalchand Ahirwar; Dheeraj Khurana; Shubhajit Roy Chowdhury
Journal:  J Med Syst       Date:  2022-10-05       Impact factor: 4.920

3.  A numerical study of the effect of varied blood pressure on the stability of carotid atherosclerotic plaque.

Authors:  Huahua Xiong; Xin Liu; Xiaohong Tian; Lina Pu; Heye Zhang; Minhua Lu; Wenhua Huang; Yuan-Ting Zhang
Journal:  Biomed Eng Online       Date:  2014-11-20       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.