Literature DB >> 18524520

Measurements of pulmonary vein ostial diameter and distance to first bifurcation: a comparison of different measurement methods.

Paul Cronin1, Ali Saab, Aine Marie Kelly, Barry H Gross, Smita Patel, Ella A Kazerooni, Ruth C Carlos.   

Abstract

The purpose of this study was to evaluate the agreement between axial, multiplanar reformatted (MPR) and semi-automated software measurements of pulmonary vein ostial diameters and distance to the first bifurcation. CT examinations of the thorax were retrospectively reviewed in 150 consecutive patients. The pulmonary vein ostial diameter and distance to the first bifurcation of the four main pulmonary veins were independently measured. The three measurement methods were compared using a Bland-Altman test. There was no significant variation between pulmonary vein ostial diameter measurements for the superior pulmonary veins across the three measurement methods. There was significant variation between the semi-automated program and both the axial (p=0.001) and MPR (p<0.001) measured diameters for the right inferior pulmonary vein ostial diameter and between the MPR and semi-automated program measurements (p=0.02) for the left inferior pulmonary vein ostial diameter. There was no significant variation between the pulmonary vein distance to first bifurcation measurements for any pulmonary vein across the three measurement methods. However, from a clinical perspective, differences were negligible; therefore, the clinician may confidently use any of the three measurement methods presented.

Entities:  

Mesh:

Year:  2008        PMID: 18524520     DOI: 10.1016/j.ejrad.2008.04.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

1.  The impact of height on recurrence after index catheter ablation of paroxysmal atrial fibrillation.

Authors:  Ching-Han Liu; Li-Wei Lo; Fa-Po Chung; Shih-Lin Chang; Yu-Feng Hu; Yenn-Jiang Lin; Shih-Chung Huang; Su-Ting Gan; Chin-Yu Lin; Tze-Fan Chao; Jo-Nan Liao; Ta-Chuan Tuan; Chih-Min Liu; Yang-Che Shiu; Cheng-I Wu; Ling Kuo; Jennifer Jeanne B Vicera; Isaiah Lugtu; Cheng-Hung Li; Yu-Cheng Hsieh; Yi-Jen Chen; Shih-Ann Chen
Journal:  J Interv Card Electrophysiol       Date:  2021-09-01       Impact factor: 1.759

2.  Diagnostic performance of CT angiography to detect pulmonary vein stenosis in children.

Authors:  Christian A Barrera; David Saul; Jordan B Rapp; Christopher L Smith; Ammie M White; David M Biko; Hansel J Otero
Journal:  Int J Cardiovasc Imaging       Date:  2019-09-09       Impact factor: 2.357

3.  Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM3PARE): method comparison algorithm implementation for head and neck IGRT positional verification.

Authors:  Anuradha Roy; Clifton D Fuller; David I Rosenthal; Charles R Thomas
Journal:  BMC Med Imaging       Date:  2015-08-28       Impact factor: 1.930

4.  Morphology and morphometry of pulmonary veins and the left atrium in multi-slice computed tomography.

Authors:  Mateusz Polaczek; Pawel Szaro; Inga Baranska; Barbara Burakowska; Bogdan Ciszek
Journal:  Surg Radiol Anat       Date:  2019-03-02       Impact factor: 1.246

5.  Normal distal pulmonary vein anatomy.

Authors:  Wiesława Klimek-Piotrowska; Mateusz K Hołda; Katarzyna Piątek; Mateusz Koziej; Jakub Hołda
Journal:  PeerJ       Date:  2016-01-14       Impact factor: 2.984

  5 in total