Literature DB >> 18524462

Hemostatic agents injected directly into hepatic injury sites for liver trauma hemorrhage under the guidance of contrast-enhanced ultrasound: an animal experiment.

Faqin Lv1, Jie Tang, Wenxiu Li, Huiqin Zhang, Wei Wang, Li Yang.   

Abstract

We investigated whether direct injection of hemostatic agents into injury sites under the guidance of contrast-enhanced ultrasound (CEUS) can decrease blood loss from liver trauma. Twelve adult healthy dogs underwent laparotomy, and a hepatic wound (6.0 x 4.5 cm) was created in each dog. All animals were divided randomly into two groups: the treatment group and the control group. In the treatment group, hemocoagulase Atrox (Solco Basle Ltd., Birsfelden, Switzerland) and absorbable cyanoacrylate were injected directly into the liver injury sites, and 0.9% normal saline was injected into the injury sites in the control group. Resuscitation volume in the treatment group was less than that in the control group (55 +/- 12 mL vs. 105 +/- 23 mL, p < 0.001). The control group presented bleeding from liver injury sites. Times of bleeding at the injury site in the treatment groups were 6 +/- 1 s. Both groups presented an-echo and/or hypo-echo contrast regions, with contrast material pooling in the injury sites before the therapy. After the injection, the contrast material pooling disappeared in the treatment group observed by CEUS. Gross examination of liver tissue revealed that the injury site that had been treated was covered by clot and glue membrane. Histopathologic examination showed that there was hemostitic glue embolizing the microvessels and inflammatory cell infiltration among hepatocytes. Direct injection of hemocoagulase Atrox and cyanoacrylate into the liver injury sites guided by CEUS can effectively reduce blood loss from liver trauma within a short time. This experimental study may suggest a possible treatment for liver trauma hemorrhage and provide an experimental evidence for treating blunt abdominal parenchyma organs trauma under the guidance of CEUS.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18524462     DOI: 10.1016/j.ultrasmedbio.2008.03.004

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Hemocoagulase atrox reduces vascular modeling in rabbit carotid artery adventitia.

Authors:  Sheng-Yun Wan; Yuan-Cheng Hu; Yan-Qing Zhan; Dan-Dan Qin; Yang Ding
Journal:  Int J Clin Exp Pathol       Date:  2013-10-15

2.  Effectiveness and safety of CEUS-guided haemostatic injection for blunt splenic trauma: an animal experiment.

Authors:  W Li; J Tang; F Lv; H Zhang; S Zhang; L An
Journal:  Radiol Med       Date:  2010-07-31       Impact factor: 3.469

3.  Establishment and evaluation of a Beagle model of grade III pancreatic trauma.

Authors:  Hanjing Gao; Qing Song; Faqin Lv; Bin Shi; Pengfei Wang; Yiru Wang; Yan Zhang; Li Yang; Yukun Luo; Xingguo Mei; Jie Tang
Journal:  Exp Ther Med       Date:  2018-08-24       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.