Literature DB >> 18524401

Dosimetric comparisons of helical tomotherapy and step-and-shoot intensity-modulated radiotherapy in nasopharyngeal carcinoma.

Tsair-Fwu Lee1, Fu-Min Fang, Pei-Ju Chao, T-J Su, Luke K Wang, Stephen W Leung.   

Abstract

PURPOSE: The study evaluates and quantifies the potential dosimetric gains of helical tomotherapy (HT) versus step-and-shoot intensity-modulated radiotherapy (SaS-IMRT) for nasopharyngeal carcinoma (NPC).
MATERIALS AND METHODS: Twenty consecutive NPC patients curatively treated by HT were examined. Each case was planned by HT and SaS-IMRT (ADAC Pinnacle(3)) planning system, respectively. Dose plans were compared using dose volume histograms (DVH), conformity index (CI), homogeneity index (HI), and minimal dose to 1cc (D(min_1cc)) of the planned target volume (PTV) and a comprehensive quality index (CQI) of ten organs at risk (OARs). The prescribed dose/fractionation was 72Gy to the PTV, 64.8Gy to the elective PTV, and 54Gy to the clinically negative neck region. The plan of 54Gy to the PTV (PTV(54)) was used to evaluate the CI and HI in the target. The cumulative doses of the three PTV plans to the OARs were calculated.
RESULTS: We observed the HT plans significantly improved the CI (improvement ratio: 11.9+/-5.5%) and HI (improvement ratio: 8.8+/-1.5%) of the PTV(54) compared with SaS-IMRT plans. In addition, the mean/maximal dose of most of the OARs except chiasm was significantly reduced in HT plans, with the CQI of 0.92+/-0.08. A negative result of HT in chiasm was observed but only significantly revealed in cases without skull base infiltration.
CONCLUSIONS: A dosimetric gain in CI and HI of PTV and sparing of OARs was significantly obtained in HT versus SaS-IMRT plans in NPC patients. Whether such dosimetric superiority in HT could transfer into clinical advantages needs further investigation.

Entities:  

Mesh:

Year:  2008        PMID: 18524401     DOI: 10.1016/j.radonc.2008.05.010

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  33 in total

1.  Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Hui-Min Ting; Su-Hua Lo; Yu-Wen Wang; Chiu-Ching Tuan; Fu-Min Fang; Te-Jen Su
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

Review 2.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

3.  Validation of an updated evidence-based protocol for proactive gastrostomy tube insertion in patients with head and neck cancer.

Authors:  T E Brown; V Getliffe; M D Banks; B G M Hughes; C Y Lin; L M Kenny; J D Bauer
Journal:  Eur J Clin Nutr       Date:  2016-02-10       Impact factor: 4.016

4.  Fatigue following radiation therapy in nasopharyngeal cancer survivors: A dosimetric analysis incorporating patient report and observer rating.

Authors: 
Journal:  Radiother Oncol       Date:  2019-01-14       Impact factor: 6.280

5.  The potential of helical tomotherapy in the treatment of head and neck cancer.

Authors:  Dirk Van Gestel; Dirk Verellen; Lien Van De Voorde; Bie de Ost; Geert De Kerf; Olivier Vanderveken; Carl Van Laer; Danielle Van den Weyngaert; Jan B Vermorken; Vincent Gregoire
Journal:  Oncologist       Date:  2013-05-30

6.  Patterns of CT lung injury and toxicity after stereotactic radiotherapy delivered with helical tomotherapy in early stage medically inoperable NSCLC.

Authors:  S Arcangeli; L Agolli; L Portalone; M R Migliorino; M G Lopergolo; A Monaco; J Dognini; M C Pressello; S Bracci; V Donato
Journal:  Br J Radiol       Date:  2015-02-03       Impact factor: 3.039

7.  Comparison between the four-field box and field-in-field techniques for conformal radiotherapy of the esophagus using dose-volume histograms and normal tissue complication probabilities.

Authors:  Farzaneh Allaveisi; Amir Nami Moghadam
Journal:  Jpn J Radiol       Date:  2017-04-18       Impact factor: 2.374

8.  Dosimetric advantages of generalised equivalent uniform dose-based optimisation on dose-volume objectives in intensity-modulated radiotherapy planning for bilateral breast cancer.

Authors:  T-F Lee; H-M Ting; P-J Chao; H-Y Wang; C-S Shieh; M-F Horng; J-M Wu; S-A Yeh; M-Y Cho; E-Y Huang; Y-J Huang; H-C Chen; F-M Fang
Journal:  Br J Radiol       Date:  2012-11       Impact factor: 3.039

Review 9.  Current status of IMRT in head and neck cancer.

Authors:  Jaime Gomez-Millan; Jesús Romero Fernández; Jose Antonio Medina Carmona
Journal:  Rep Pract Oncol Radiother       Date:  2013-10-20

10.  Helical tomotherapy for single and multiple liver tumours.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Fu-Min Fang; Te-Jen Su; Stephen W Leung; Hsuan-Chih Hsu
Journal:  Radiat Oncol       Date:  2010-06-24       Impact factor: 3.481