Literature DB >> 1852381

Transscleral cyclophotocoagulation using a semiconductor diode laser in cadaver eyes.

H L Hennis1, E Assia, W C Stewart, U F Legler, D J Apple.   

Abstract

We studied the effectiveness of semiconductor diode laser transscleral cyclophotocoagulation in cadaver eyes using the Miyake technique and light microscopy. Thermal lesions in the ciliary processes were induced with 0.7-second, 1200-mW, and 100- to 500-microns applications, 0.5 mm from the surgical limbus and defocused 1 mm posteriorly. An effective ciliary body reaction was observed grossly as tissue blanching, shrinkage, and pigment dispersion; and histologically, as coagulation necrosis and epithelial cell disruption. No damage to crystalline or intraocular lenses was evident. This successful application of diode laser transscleral cyclophotocoagulation in cadaver eyes suggests that it may prove useful in treating patients with glaucoma.

Entities:  

Mesh:

Year:  1991        PMID: 1852381

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  6 in total

1.  Comparison of acute structural and histopathological changes in human autopsy eyes after endoscopic cyclophotocoagulation and trans-scleral cyclophotocoagulation.

Authors:  Mina B Pantcheva; Malik Y Kahook; Joel S Schuman; Robert J Noecker
Journal:  Br J Ophthalmol       Date:  2006-09-20       Impact factor: 4.638

2.  Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography.

Authors:  H Hoerauf; M Müller; G Hüttmann; C Winter; T Schlote
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-09-28       Impact factor: 3.117

3.  The UK National Cyclodiode Laser Survey.

Authors:  P Agrawal; S Dulku; W Nolan; V Sung
Journal:  Eye (Lond)       Date:  2010-12-03       Impact factor: 3.775

4.  Clinical comparison of semiconductor diode versus neodymium: YAG non-contact cyclo photocoagulation.

Authors:  M W Ulbig; D A McHugh; A I McNaught; A M Hamilton
Journal:  Br J Ophthalmol       Date:  1995-06       Impact factor: 4.638

5.  Microwave cyclodestruction: evaluation on human eyes.

Authors:  P T Finger; H D Perry; J L Shakin; D R Bisciotti; R J Nattis
Journal:  Br J Ophthalmol       Date:  1995-07       Impact factor: 4.638

6.  Diode laser contact transscleral retinal photocoagulation: a clinical study.

Authors:  D A McHugh; S Schwartz; J G Dowler; M Ulbig; R K Blach; P A Hamilton
Journal:  Br J Ophthalmol       Date:  1995-12       Impact factor: 4.638

  6 in total