Literature DB >> 18520564

Dual energy subtraction and temporal subtraction chest radiography.

Heber MacMahon1, Feng Li, Roger Engelmann, Rachael Roberts, Samuel Armato.   

Abstract

Digital radiography and display systems have revolutionized radiologic practice in recent years and have enabled clinical application of advanced image processing techniques. These include dual energy subtraction and temporal subtraction, both of which can improve diagnostic accuracy for abnormal findings in chest radiographs, especially for subtle lesions such as early lung cancer or focal pneumonia. Dual energy radiography exploits the differential attenuation of low-energy x-ray photons by calcium to produce separate images on the bones and soft tissues, which provides improved detection and characterization of both calcified and noncalcified lung lesions. Dual energy subtraction radiography is currently available from 2 of the major vendors and is in clinical use at many institutions in the United States. Temporal subtraction is a complementary technique that enhances interval change, by using a previous radiograph as a subtraction mask, so that unchanged normal anatomy is suppressed, whereas new abnormalities are enhanced. Though it is not yet a product in the United States, temporal subtraction is available for clinical use in Japan. Temporal subtraction can be combined with energy subtraction to reduce misregistration artifacts, and also has potential to improve computer-aided detection of nodules and other types of lung disease.

Entities:  

Mesh:

Year:  2008        PMID: 18520564     DOI: 10.1097/RTI.0b013e318173dd38

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  13 in total

1.  Improved detection of focal pneumonia by chest radiography with bone suppression imaging.

Authors:  Feng Li; Roger Engelmann; Lorenzo Pesce; Samuel G Armato; Heber Macmahon
Journal:  Eur Radiol       Date:  2012-07-05       Impact factor: 5.315

2.  Multiscale deformable registration for dual-energy x-ray imaging.

Authors:  G J Gang; C A Varon; H Kashani; S Richard; N S Paul; R Van Metter; J Yorkston; J H Siewerdsen
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

Review 3.  Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

Authors:  Feng Li
Journal:  Radiol Phys Technol       Date:  2015-05-17

4.  Evaluation of a template-based algorithm for markerless lung tumour localization on single- and dual-energy kilovoltage images.

Authors:  Alec M Block; Rakesh Patel; Murat Surucu; Matthew M Harkenrider; John C Roeske
Journal:  Br J Radiol       Date:  2016-10-12       Impact factor: 3.039

5.  Small lung cancers: improved detection by use of bone suppression imaging--comparison with dual-energy subtraction chest radiography.

Authors:  Feng Li; Roger Engelmann; Lorenzo L Pesce; Kunio Doi; Charles E Metz; Heber Macmahon
Journal:  Radiology       Date:  2011-09-23       Impact factor: 11.105

6.  Optimization of dual-energy subtraction chest radiography by use of a direct-conversion flat-panel detector system.

Authors:  Mari Fukao; Kiyosumi Kawamoto; Hiroaki Matsuzawa; Osamu Honda; Takeshi Iwaki; Tsukasa Doi
Journal:  Radiol Phys Technol       Date:  2014-08-15

7.  Chest tomosynthesis: technical principles and clinical update.

Authors:  James T Dobbins; H Page McAdams
Journal:  Eur J Radiol       Date:  2009-07-18       Impact factor: 3.528

8.  Automatic screening for tuberculosis in chest radiographs: a survey.

Authors:  Stefan Jaeger; Alexandros Karargyris; Sema Candemir; Jenifer Siegelman; Les Folio; Sameer Antani; George Thoma
Journal:  Quant Imaging Med Surg       Date:  2013-04

9.  Efficiency and reporting confidence analysis of sequential dual-energy subtraction for thoracic x-ray examinations.

Authors:  Mehmet Can Gezer; Oktay Algin; Aytac Durmaz; Halil Arslan
Journal:  Qatar Med J       Date:  2019-09-23

10.  Smart spotting of pulmonary TB cavities using CT images.

Authors:  V Ezhil Swanly; L Selvam; P Mohan Kumar; J Arokia Renjith; M Arunachalam; K L Shunmuganathan
Journal:  Comput Math Methods Med       Date:  2013-12-03       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.