Descemet-stripping automated endothelial keratoplasty (DSAEK): effect of nontoxic gentian violet marking pen on DSAEK donor tissue viability by using vital dye assay.

Takeshi Ide1, Sonia H Yoo, George D Kymionis, Victor L Perez, James M Goldman, Terrence P O'Brien.   

Abstract

PURPOSE: To qualitatively assess the endothelial damage on Descemet-stripping automated endothelial keratoplasty (DSAEK) donor tissue resulting from a gentian violet marking pen.
METHODS: An in vitro model was used, by using corneoscleral rims, DSAEK quality corneal donor tissue, and a gentian violet marking pen. After making a mark on the stromal side of a microkeratome-prepared DSAEK corneal button to confirm appropriate orientation of the donor tissue after insertion into the anterior chamber, the corneal tissue was returned to Optisol GS solution for 1 hour. A vital dye assay was used to identify devitalized and necrotic endothelial cells with alizarin red S and trypan blue.
RESULTS: Corneal donor tissue evaluated with the gentian violet marking pen showed positive trypan blue staining, limited to the area marked with the gentian violet ink.
CONCLUSIONS: Marking the DSAEK donor stromal surface with a gentian violet marker damages the endothelium. Surgeons should limit the size of the mark or use an insertion technique that avoids confusion about orientation of the donor cornea.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18520506     DOI: 10.1097/ICO.0b013e318165841f

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Clinical results after single asymmetrical shark fin for graft orientation in DMEK.

Authors:  Annekatrin Rickmann; Karl Boden; André M Trouvain; Lisa J Müller; Catheline Bocqué; Sebastian Thaler; Peter Szurman
Journal:  Int Ophthalmol       Date:  2021-10-31       Impact factor: 2.031

Review 2.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

Review 3.  Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices.

Authors:  Salman Nasir Khan; Panos S Shiakolas; Venkateswara Vinod Mootha
Journal:  J Ophthalmic Vis Res       Date:  2015 Oct-Dec

4.  The Use of Polarization Filters to Detect the Edge of the Descemet's Stripping Automated Endothelial Keratoplasty(DSAEK) Graft.

Authors:  Takeshi Ide; Sonia H Yoo; Terrence P O'Brien
Journal:  Open Ophthalmol J       Date:  2009-02-03

5.  An ink surgical marker pen is damaging to tendon cells.

Authors:  S L Franklin; C Jayadev; R Poulsen; P Hulley; A Price
Journal:  Bone Joint Res       Date:  2012-03-01       Impact factor: 5.853

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.