Feasibility of noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years.

Peter Andriessen1, Olaf Schraa, Wendy van Den Bosch-Ruis, Derk Jan Ten Harkel, Jos J Settels, Sidarto Bambang Oetomo, Carlos E Blanco.   

Abstract

Our goal was to study the feasibility of continuous noninvasive finger blood pressure (BP) monitoring in very young children, aged 0-4 y. To achieve this, we designed a set of small-sized finger cuffs based on the assessment of finger circumference. Finger arterial BP measured by a volume clamp device (Finapres technology) was compared with simultaneously measured intra-arterial BP in 15 very young children (median age, 5 mo; range, 0-48), admitted to the intensive care unit for vital monitoring. The finger cuff-derived BP waveforms showed good resemblance with the invasive arterial waveforms (mean root-mean-square error, 3 mm Hg). The correlation coefficient between both methods was 0.79 +/- 0.19 systolic and 0.74 +/- 0.24 diastolic. The correlation coefficient of beat-to-beat changes between both methods was 0.82 +/- 0.18 and 0.75 +/- 0.21, respectively. Three measurements were related to measurement errors (loose cuff application; wrong set-point). Excluding these erroneous measurements resulted in clinically acceptable measurement bias (-3.8 mm Hg) and 95% limits of agreement (-10.4 to + 2.8 mm Hg) of mean BP values. We conclude that continuous finger BP measurement is feasible in very young children. However, cuff application is critical, and the current set-point algorithm needs to be revised in very young children.

Entities:  

Mesh:

Year:  2008        PMID: 18520333     DOI: 10.1203/PDR.0b013e31816c8fe3

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  3 in total

1.  Positional circulatory control in the sleeping infant and toddler: role of the inner ear and arterial pulse pressure.

Authors:  Gary Cohen; Silvano Vella; Heather Jeffery; Hugo Lagercrantz; Miriam Katz-Salamon
Journal:  J Physiol       Date:  2012-05-14       Impact factor: 5.182

2.  Baroreflex dysfunction in sick newborns makes heart rate an unreliable surrogate for blood pressure changes.

Authors:  Rathinaswamy B Govindan; Tareq Al-Shargabi; An N Massaro; Marina Metzler; Nickie N Andescavage; Radhika Joshi; Rhiya Dave; Adre du Plessis
Journal:  Pediatr Res       Date:  2016-02-09       Impact factor: 3.756

Review 3.  Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review.

Authors:  Malak Abdullah Almarshad; Md Saiful Islam; Saad Al-Ahmadi; Ahmed S BaHammam
Journal:  Healthcare (Basel)       Date:  2022-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.