Performance of a non-fluoroscopically assisted substitute for the Lyon schuss knee radiograph: quality and reproducibility of positioning and sensitivity to joint space narrowing in osteoarthritic knees.

S A Mazzuca1, M-P Hellio Le Graverand, E Vignon, D J Hunter, C G Jackson, V B Kraus, T M Link, T J Schnitzer, A Vaz, H C Charles.   

Abstract

OBJECTIVE: This study evaluated the longitudinal performance of a modified Lyon schuss (LS) knee examination in the detection of radiographic joint space narrowing (JSN) in knees with osteoarthritis (OA). The modified LS exam entails two to four iterative acquisitions with empirically adjusted angulation of the X-ray beam to achieve superimposition of the anterior and posterior margins of the medial tibial plateau (MTP), a marker of parallel radioanatomic alignment that the original LS exam achieves with fluoroscopically guided beam angulation.
METHODS: Seventy-four obese women with symptomatic knee OA underwent LS and fixed-flexion (FF, caudal 10 degrees beam angulation) X-ray exams at baseline and 1 year later. For 47 subjects, beam angulation for both LS exams was guided by fluoroscopy. For 27 subjects, the modified LS exam was performed at one or both times. Modified and original LS procedures were evaluated relative to concurrent FF radiographs with respect to the inter-margin distance (IMD) at the MTP midpoint (quality and reproducibility of alignment) and sensitivity to JSN.
RESULTS: Compared to FF radiographs, modified LS radiographs afforded a smaller mean IMD at baseline (0.89 vs 2.06 mm, P=0.002), more reproducible IMD (mean change=0.49 vs 0.91 mm, P=0.007) and more rapid JSN (mean=0.25 vs 0.02 mm/yr, P=0.005). These differences paralleled those observed between original LS and FF procedures with respect to baseline alignment (0.96 vs 1.94 mm, P<0.001), reproducibility of alignment (0.49 vs 1.00 mm, P<0.001) and sensitivity to JSN (0.16 vs -0.01 mm/yr, P=0.007).
CONCLUSION: In clinical centers where the absence of fluoroscopy equipment precludes use of the original LS protocol, a modified procedure employing iterative, empirical adjustment of the beam angle to achieve parallel radioanatomic alignment with the MTP affords a degree of superiority over the FF protocol with respect to quality and reproducibility of positioning and sensitivity to JSN in OA knees similar to that of the original.

Entities:  

Mesh:

Year:  2008        PMID: 18515156     DOI: 10.1016/j.joca.2008.04.010

Source DB:  PubMed          Journal:  Osteoarthritis Cartilage        ISSN: 1063-4584            Impact factor:   6.576


  14 in total

1.  Cross-sectional comparison of extended anteroposterior and posteroanterior fixed flexion positioning to assess radiographic osteoarthritis at the knee: the Johnston County Osteoarthritis Project.

Authors:  Amanda E Nelson; Jordan B Renner; Xiaoyan A Shi; Jack H Shreffler; Todd A Schwartz; Joanne M Jordan
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-09       Impact factor: 4.794

2.  Alignment of the medial tibial plateau affects the rate of joint space narrowing in the osteoarthritic knee.

Authors:  E Vignon; K D Brandt; C Mercier; M Hochberg; D Hunter; S Mazzuca; K Powell; B Wyman; M-P Hellio Le Graverand
Journal:  Osteoarthritis Cartilage       Date:  2010-09-08       Impact factor: 6.576

3.  One-year change in radiographic joint space width in patients with unilateral joint space narrowing: data from the Osteoarthritis Initiative.

Authors:  O D Benichou; D J Hunter; D R Nelson; A Guermazi; F Eckstein; K Kwoh; S L Myers; W Wirth; J Duryea
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-07       Impact factor: 4.794

4.  Effect of High-Intensity Strength Training on Knee Pain and Knee Joint Compressive Forces Among Adults With Knee Osteoarthritis: The START Randomized Clinical Trial.

Authors:  Stephen P Messier; Shannon L Mihalko; Daniel P Beavers; Barbara J Nicklas; Paul DeVita; J Jeffery Carr; David J Hunter; Mary Lyles; Ali Guermazi; Kim L Bennell; Richard F Loeser
Journal:  JAMA       Date:  2021-02-16       Impact factor: 56.272

Review 5.  Responsiveness to change and reliability of measurement of radiographic joint space width in osteoarthritis of the knee: a systematic review.

Authors:  W M Reichmann; J F Maillefert; D J Hunter; J N Katz; P G Conaghan; E Losina
Journal:  Osteoarthritis Cartilage       Date:  2011-03-23       Impact factor: 6.576

6.  Patellar skin surface temperature by thermography reflects knee osteoarthritis severity.

Authors:  Anna E Denoble; Norine Hall; Carl F Pieper; Virginia B Kraus
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2010-10-15

7.  Direct comparison of fixed flexion, radiography and MRI in knee osteoarthritis: responsiveness data from the Osteoarthritis Initiative.

Authors:  W Wirth; J Duryea; M-P Hellio Le Graverand; M R John; M Nevitt; R J Buck; F Eckstein
Journal:  Osteoarthritis Cartilage       Date:  2012-11-02       Impact factor: 6.576

8.  Subchondral bone trabecular integrity predicts and changes concurrently with radiographic and magnetic resonance imaging-determined knee osteoarthritis progression.

Authors:  Virginia Byers Kraus; Sheng Feng; ShengChu Wang; Scott White; Maureen Ainslie; Marie-Pierre Hellio Le Graverand; Alan Brett; Felix Eckstein; David J Hunter; Nancy E Lane; Mihra S Taljanovic; Thomas Schnitzer; H Cecil Charles
Journal:  Arthritis Rheum       Date:  2013-07

9.  Strength Training for Arthritis Trial (START): design and rationale.

Authors:  Stephen P Messier; Shannon L Mihalko; Daniel P Beavers; Barbara J Nicklas; Paul DeVita; J Jeffery Carr; David J Hunter; Jeff D Williamson; Kim L Bennell; Ali Guermazi; Mary Lyles; Richard F Loeser
Journal:  BMC Musculoskelet Disord       Date:  2013-07-15       Impact factor: 2.362

10.  The Intensive Diet and Exercise for Arthritis (IDEA) trial: design and rationale.

Authors:  Stephen P Messier; Claudine Legault; Shannon Mihalko; Gary D Miller; Richard F Loeser; Paul DeVita; Mary Lyles; Felix Eckstein; David J Hunter; Jeff D Williamson; Barbara J Nicklas
Journal:  BMC Musculoskelet Disord       Date:  2009-07-28       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.