Literature DB >> 18512844

Mass defect profiles of biological matrices and the general applicability of mass defect filtering for metabolite detection.

Haiying Zhang1, Mingshe Zhu, Kenneth L Ray, Li Ma, Donglu Zhang.   

Abstract

Recent examples have demonstrated that the high-resolution liquid chromatography/mass spectrometry (LC/MS)-based mass defect filtering (MDF) technique was effective in selectively detecting drug metabolites regardless of their molecular weights or fragmentation patterns. The main objective of the current study was to evaluate the general applicability of MDF for drug metabolite detection in typical biological matrices. Mass defect profiles of commonly used biological matrices including plasma, urine, bile, and feces were obtained using an LTQ FT mass spectrometer and were compared with those of 115 commonly prescribed drugs. The mass defect profiles were presented as two-dimensional Y-X plots with the determined mass defects of components on the y-axis versus the corresponding m/z values on the x-axis. The mass defect profiles of the matrices appeared to be similar for each type of matrix across species, yet marked differences were apparent between matrices of a given species. The mass defect profiles of components in plasma, bile, and feces showed significant separation from most of the 115 drugs. The mass defect profiles of urine did not show such clean separation from that of the 115 drugs. The results suggest that MDF has a broad applicability for selective detection of drug metabolites in plasma, bile and feces although the selectivity for detecting urinary drug metabolites is not as good as in the other matrices. In addition, the mass defect profiles of the biological matrices allow for prediction of the effectiveness of MDF for certain applications, and for designing specific MDF windows for selective detection of drug metabolites.

Mesh:

Substances:

Year:  2008        PMID: 18512844     DOI: 10.1002/rcm.3585

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  10 in total

1.  Halogenated peptides as internal standards (H-PINS): introduction of an MS-based internal standard set for liquid chromatography-mass spectrometry.

Authors:  Hamid Mirzaei; Mi-Youn Brusniak; Lukas N Mueller; Simon Letarte; Julian D Watts; Ruedi Aebersold
Journal:  Mol Cell Proteomics       Date:  2009-05-01       Impact factor: 5.911

Review 2.  Drug metabolite profiling and identification by high-resolution mass spectrometry.

Authors:  Mingshe Zhu; Haiying Zhang; W Griffith Humphreys
Journal:  J Biol Chem       Date:  2011-06-01       Impact factor: 5.157

3.  Non-linear classification for on-the-fly fractional mass filtering and targeted precursor fragmentation in mass spectrometry experiments.

Authors:  Marc Kirchner; Wiebke Timm; Peying Fong; Philine Wangemann; Hanno Steen
Journal:  Bioinformatics       Date:  2010-02-04       Impact factor: 6.937

4.  The Application of Mass Spectrometry in Drug Metabolism and Pharmacokinetics.

Authors:  Ji-Yoon Lee; Sang Kyum Kim; Kiho Lee; Soo Jin Oh
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

5.  Comparison of chemometric strategies for potential exposure marker discovery and false-positive reduction in untargeted metabolomics: application to the serum analysis by LC-HRMS after intake of Vaccinium fruit supplements.

Authors:  Lapo Renai; Claudia Ancillotti; Marynka Ulaszewska; Mar Garcia-Aloy; Fulvio Mattivi; Riccardo Bartoletti; Massimo Del Bubba
Journal:  Anal Bioanal Chem       Date:  2022-01-14       Impact factor: 4.142

6.  Bioassay-directed fractionation for discovery of bioactive neutral lipids guided by relative mass defect filtering and multiplexed collision-induced dissociation.

Authors:  Michael C Stagliano; Joshua G DeKeyser; Curtis J Omiecinski; A Daniel Jones
Journal:  Rapid Commun Mass Spectrom       Date:  2010-12-30       Impact factor: 2.419

Review 7.  Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome.

Authors:  Syam S Andra; Christine Austin; Dhavalkumar Patel; Georgia Dolios; Mahmoud Awawda; Manish Arora
Journal:  Environ Int       Date:  2017-01-04       Impact factor: 9.621

8.  Advances in structure elucidation of small molecules using mass spectrometry.

Authors:  Tobias Kind; Oliver Fiehn
Journal:  Bioanal Rev       Date:  2010-08-21

9.  Isotopic signature transfer and mass pattern prediction (IsoStamp): an enabling technique for chemically-directed proteomics.

Authors:  Krishnan K Palaniappan; Austin A Pitcher; Brian P Smart; David R Spiciarich; Anthony T Iavarone; Carolyn R Bertozzi
Journal:  ACS Chem Biol       Date:  2011-06-16       Impact factor: 5.100

10.  Spectrum-Effect Relationship Analysis of Bioactive Compounds in Zanthoxylum nitidum (Roxb.) DC. by Ultra-High Performance Liquid Chromatography Mass Spectrometry Coupled With Comprehensive Filtering Approaches.

Authors:  Si-Wei Rao; Yuan-Yuan Duan; Han-Qing Pang; Shao-Hua Xu; Shou-Qian Hu; Ke-Guang Cheng; Dong Liang; Wei Shi
Journal:  Front Pharmacol       Date:  2022-03-09       Impact factor: 5.810

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.