Literature DB >> 18508068

Ion-trap versus time-of-flight mass spectrometry coupled to capillary electrophoresis to analyze biogenic amines in wine.

Carolina Simó1, M Victoria Moreno-Arribas, Alejandro Cifuentes.   

Abstract

In this work, two different capillary electrophoresis-mass spectrometry (CE-MS) methods, namely, capillary electrophoresis-ion-trap mass spectrometry (CE-IT-MS) and capillary electrophoresis-time-of-flight mass spectrometry (CE-TOF-MS), applied to analyze biogenic amines in wine samples are investigated. A group of five amines was selected as case study (namely, putrescine, cadaverine, histamine, phenylethylamine and tyramine) since they are the most frequently biogenic amines found in wines. The possibilities of both instruments in terms of sensitivity, selectivity and quantitation during the determination of the mentioned biogenic amines in wine samples was studied and their results corroborated by HPLC. After optimization of the analytical conditions, CE-IT-MS and CE-TOF-MS allowed the identification of biogenic amines in wines without any previous treatment except diluting 1:1 with water and filtering. Biogenic amines were determined in three red wines and one white wine showing, as expected, a higher concentration in red wines. Moreover, CE-IT-MS and CE-TOF-MS were compared regarding their capacity to detect other biogenic amines different to the selected ones in wine samples, showing CE-TOF-MS a much better capability (i.e., putrescine, cadaverine, histamine, phenylethylamine, tyramine, triptamine, spermidine, spermine, ethanolamine and isoamylamine were identified by CE-TOF-MS in a single analysis). Moreover, CE-TOF-MS allowed the quantitation of biogenic amines with limits of detection as low as 10 ng/mL, comparable to those obtained using HPLC with fluorescence detection, without any previous derivatization step and with analysis times fivefold faster (40 min by HPLC and 8 min by CE-TOF-MS).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18508068     DOI: 10.1016/j.chroma.2008.05.004

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Quantification of histamine in various fish samples using square wave stripping voltammetric method.

Authors:  Ummihan Taskoparan Yilmaz; Derya Inan
Journal:  J Food Sci Technol       Date:  2015-02-10       Impact factor: 2.701

2.  The apoptosis-inducing activity towards leukemia and lymphoma cells in a cyanobacterial culture collection is not associated with mouse bioassay toxicity.

Authors:  Linn Oftedal; Kaja H Skjærven; Rosie T Coyne; Bente Edvardsen; Thomas Rohrlack; Olav M Skulberg; Stein Ove Døskeland; Lars Herfindal
Journal:  J Ind Microbiol Biotechnol       Date:  2010-08-06       Impact factor: 3.346

3.  Polyamines in biological samples: rapid and robust quantification by solid-phase extraction online-coupled to liquid chromatography-tandem mass spectrometry.

Authors:  Christoph Magnes; Alexander Fauland; Edgar Gander; Sophie Narath; Maria Ratzer; Tobias Eisenberg; Frank Madeo; Thomas Pieber; Frank Sinner
Journal:  J Chromatogr A       Date:  2014-01-14       Impact factor: 4.759

4.  High Performance Liquid Chromatography versus Stacking-Micellar Electrokinetic Chromatography for the Determination of Potentially Toxic Alkenylbenzenes in Food Flavouring Ingredients.

Authors:  Huynh N P Dang; Joselito P Quirino
Journal:  Molecules       Date:  2021-12-21       Impact factor: 4.411

5.  Spermidine, but not spermine, is essential for pigment pattern formation in zebrafish.

Authors:  Hans Georg Frohnhöfer; Silke Geiger-Rudolph; Martin Pattky; Martin Meixner; Carolin Huhn; Hans-Martin Maischein; Robert Geisler; Ines Gehring; Florian Maderspacher; Christiane Nüsslein-Volhard; Uwe Irion
Journal:  Biol Open       Date:  2016-06-15       Impact factor: 2.422

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.