Literature DB >> 1850784

Cardiac blood-pool scintigraphy in rats and hamsters: comparison of five radiopharmaceuticals and three pinhole collimator apertures.

P Pieri1, A J Fischman, M Ahmad, R H Moore, R J Callahan, H W Strauss.   

Abstract

Preclinical evaluation of cardiac drugs may require evaluation of cardiac function in intact animals. To optimize the quality of radionuclide measurements of ventricular function in small animals, a comparison was made of gated blood-pool scans recorded with five blood-pool radiopharmaceuticals (99mTc-labeled human polyclonal IgG, 99mTc-human serum albumin labeled by two methods, and red blood cells radiolabeled with 99mTc via in vivo and in vitro methods) in rats and three pinhole apertures in hamsters. The quality of the radiopharmaceuticals was evaluated by comparing count density ratios (LV/BACKGROUND and LV/LIVER) and ejection fractions recorded with each agent. The edge definition of the left ventricle and count rate performance of the 1-, 2-, and 3-mm apertures was evaluated in hamsters. In general, the images obtained with the radiolabeled cells were superior to those obtained with the labeled proteins and no significant differences between the protein preparations were detected. Left ventricular ejection fractions calculated with all five radiopharmaceuticals were not significantly different. The best quality images were obtained with the 1-mm pinhole collimator. Ejection fraction and acquisition time were inversely related to aperture size. A good compromise between resolution and sensitivity was obtained with the 2-mm pinhole collimator.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1850784

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

Review 1.  Monitoring left ventricular function in small animals.

Authors:  Tony Lahoutte
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

2.  Progression of detail.

Authors: 
Journal:  J Nucl Cardiol       Date:  2000-03       Impact factor: 5.952

3.  First evaluation of technetium-99m dimercaptopropionyl albumin as a possible tracer agent for ventriculography in a volunteer.

Authors:  K A Verbeke; W B Vanhecke; L A Mortelmans; A M Verbruggen
Journal:  Eur J Nucl Med       Date:  1994-09

4.  Pinhole imaging of 131I-metaiodobenzylguanidine (131I-MIBG) in an animal model of neuroblastoma.

Authors:  Roberto Accorsi; Michael J Morowitz; Martin Charron; John M Maris
Journal:  Pediatr Radiol       Date:  2003-08-08

5.  Comparison between Radionuclide Ventriculography and Echocardiography for Quantification of Left Ventricular Systolic Function in Rats Exposed to Doxorubicin.

Authors:  Luciano Fonseca Lemos de Oliveira; João Lucas O'Connell; Eduardo Elias Vieira de Carvalho; Érica Carolina Campos Pulici; Minna Moreira Dias Romano; Benedito Carlos Maciel; Marcus Vinicius Simões
Journal:  Arq Bras Cardiol       Date:  2017-01       Impact factor: 2.000

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.