Literature DB >> 18506720

Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles.

João Aris Kouyoumdjian1, Erik V Stålberg.   

Abstract

The aim of this study was to estimate normal jitter in voluntarily activated extensor digitorum communis (EDC) and orbicularis oculi (OOc) muscles using a disposable concentric needle electrode (CNE). The EDC of 67 normal subjects (22 males and 45 females, mean age 35.5 +/- 10.2 years) and the OOc of 50 normal subjects (13 males and 37 females, mean age 37.9 +/- 9.6 years) were studied. Jitter values were expressed as the mean consecutive difference (MCD) of 20 potential pairs. The mean MCD for EDC was 23.6 +/- 3.1 micros (upper 95% confidence limit [CL]: 29.7 micros). The mean MCD of all potential pairs (n = 1340) was 23.5 +/- 7.3 micros (95% CL: 38.2 micros). The mean MCD for the 18th highest value was 31.4 +/- 4.9 micros (95% CL: 41.2 micros). The mean MCD for OOc was 24.7 +/- 3.1 micros (95% CL: 31.0 micros). The mean MCD of all potential pairs (n = 1000) was 24.7 +/- 7.1 micros (95% CL: 39.0 micros). The mean MCD for the 18th highest value was 32.7 +/- 4.1 micros (95% CL: 40.9 micros). Our reported CNE jitter values obtained during voluntary activation represent the largest series currently available. The suggested practical limit in the EDC for mean MCD was 30 mus and for outliers was 42 micros, and in the OOc for mean MCD was 31 micros and 41 micros for outliers. The present study confirms that CNE can be used to assess jitter values, although certain precautions must be taken.

Entities:  

Mesh:

Year:  2008        PMID: 18506720     DOI: 10.1002/mus.21043

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  8 in total

1.  Application of futility analysis to refine jitter recordings in myasthenia gravis.

Authors:  Pushpa Narayanaswami; Norberto Pantoja-Galicia; Rebecca A Betensky; Seward B Rutkove
Journal:  Muscle Nerve       Date:  2012-04       Impact factor: 3.217

2.  Jitter Values on Voluntary Active Periocular Muscles of Healthy Subjects with Conventional (37 mm) Concentric Needle Electrode.

Authors:  Leyla Baysal Kiraç; Elif Kocasoy Orhan; Saygın Gönderten; Mehmet Barış Baslo; Ali Emre Öge
Journal:  Noro Psikiyatr Ars       Date:  2016-06-01       Impact factor: 1.339

3.  Recovery of brachial plexus lesions resulting from heavy backpack use: a follow-up case series.

Authors:  Tuula Nylund; Ville M Mattila; Tapani Salmi; Harri K Pihlajamäki; Jyrki P Mäkelä
Journal:  BMC Musculoskelet Disord       Date:  2011-03-24       Impact factor: 2.362

4.  Concentric Needle Jitter in 97 Myasthenia Gravis Patients.

Authors:  João Aris Kouyoumdjian; Gabriel Pina Paiva; Erik Stålberg
Journal:  Front Neurol       Date:  2020-11-13       Impact factor: 4.003

5.  Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle.

Authors:  João Aris Kouyoumdjian; Carla Renata Graca
Journal:  Front Neurol       Date:  2022-07-22       Impact factor: 4.086

Review 6.  Contribution of Single-Fiber Evaluation on Monitoring Outcomes Following Injection of Botulinum Toxin-A: A Narrative Review of the Literature.

Authors:  Hélène Moron; Corine Gagnard-Landra; David Guiraud; Arnaud Dupeyron
Journal:  Toxins (Basel)       Date:  2021-05-17       Impact factor: 4.546

7.  Electrophysiological study in neuromuscular junction disorders.

Authors:  Ajith Cherian; Neeraj N Baheti; Thomas Iype
Journal:  Ann Indian Acad Neurol       Date:  2013-01       Impact factor: 1.383

8.  Quantitating Changes in Jitter and Spike Number Using Concentric Needle Electrodes in Amyotrophic Lateral Sclerosis Patients.

Authors:  Ming-Sheng Liu; Jing-Wen Niu; Yi Li; Yu-Zhou Guan; Li-Ying Cui
Journal:  Chin Med J (Engl)       Date:  2016-05-05       Impact factor: 2.628