Literature DB >> 18506056

A novel platform device for rodent echocardiography.

Ingo Kutschka1, Ahmad Y Sheikh, Ramachandra Sista, Stephen L Hendry, Hyung J Chun, Grant Hoyt, Werner Kutschka, Marc P Pelletier, Tom Quertermous, Joseph C Wu, Robert C Robbins.   

Abstract

Acquisition of echocardiographic data from rodents is subject to wide variability due to variations in technique. We hypothesize that a dedicated imaging platform can aid in standardization of technique and improve the quality of images obtained. We constructed a device consisting of a boom-mounted steel platform frame (25 x 35 x 3 cm) on which a transparent polyethylene membrane is mounted. The animal is placed onto the membrane and receives continual inhaled anesthesia via an integrated port. The membrane allows for probe positioning from beneath the animal to obtain standard echo-views in left lateral decubitus or prone positions. The frame can be set at any desired angle ranging from 0 to 360 degrees along either the long or short axis. Adult male Sprague-Dawley rats (n = 5) underwent echocardiography (General Electric, Vivid 7, 14 MHz) using the platform. The device allowed for optimal positioning of animals for a variety of standard echocardiographic measurements. Evaluations among all animals showed minimal variability between two different operators and time points. We tested the feasibility of the device for supporting the assessment of cardiac function in a disease model by evaluating a separate cohort of adult male spontaneously hypertensive rats (n = 5) that underwent left anterior descending coronary artery ligation. Serial echocardiography demonstrated statistically significant decreases of fractional shortening and ejection fraction (p < 0.01) 240 days after surgery. Our novel imaging platform allowed for consistent collection of high-quality echocardiographic data from rats. Future studies will focus on improving this technology to allow for standardized high-throughput echocardiographic analysis in small animal models of disease.

Entities:  

Mesh:

Year:  2007        PMID: 18506056     DOI: 10.1093/ilar.49.2.e1

Source DB:  PubMed          Journal:  ILAR J        ISSN: 1084-2020


  4 in total

Review 1.  New approaches in small animal echocardiography: imaging the sounds of silence.

Authors:  Rashmi Ram; Deanne M Mickelsen; Catherine Theodoropoulos; Burns C Blaxall
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-08-26       Impact factor: 4.733

2.  Comparisons of High Intensity Interval Training and Continuous Training on Metabolomic Alteration and Cardiac Function in Male Adolescent Rats.

Authors:  Molin Zheng; Chuanan Liu; Yuanyuan Lv; Jing Mi; Dan Qiu; Lingxiao He; Li Zhao
Journal:  Front Physiol       Date:  2022-06-28       Impact factor: 4.755

3.  Prenatal exposure to lipopolysaccharide results in myocardial remodelling in adult murine offspring.

Authors:  Yanling Wei; Wenhua Du; Xiuqin Xiong; Xiaoyan He; Youcai Deng; Dongfeng Chen; Xiaohui Li
Journal:  J Inflamm (Lond)       Date:  2013-11-19       Impact factor: 4.981

Review 4.  Rat Heterotopic Heart Transplantation Model to Investigate Unloading-Induced Myocardial Remodeling.

Authors:  Xuebin Fu; Adrian Segiser; Thierry P Carrel; Hendrik T Tevaearai Stahel; Henriette Most
Journal:  Front Cardiovasc Med       Date:  2016-10-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.