1.0-M gadobutrol versus 0.5-M gadoterate for peripheral magnetic resonance angiography: a prospective randomized controlled clinical trial.

Zsolt Szucs-Farkas1, Johannes M Froehlich, Martin Ulrich, Hans-Ueli Wuersten, Dominique Guignard, Sandra Wyss, Marianne Braunschweig.   

Abstract

PURPOSE: To perform a quantitative and qualitative comparison of gadobutrol and gadoterate in three-station contrast enhanced magnetic resonance angiography (CE-MRA) of the lower limbs.
MATERIALS AND METHODS: In this prospective randomized controlled trial, 52 patients with leg ischemia were randomly assigned to one of two groups receiving either gadobutrol (1.0 mmol Gd/mL, 15 mL) or gadoterate (0.5 mmol Gd/mL, 30 mL). Three-station 3D CE-MRAs from the pelvis to the ankles were performed with moving-table technique on a 1.5T MR scanner. Injection time was identical in both groups. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for 816 arteries. Contrast quality in 1196 vessel segments was evaluated separately by two blinded readers on a three-point scale.
RESULTS: Mean SNR (61.8 +/- 7.8 for gadobutrol vs. 61.9 +/- 9.1 for gadoterate, P = 0.257), CNR (52.8 +/- 9.1 vs. 52.8 +/- 10.7, P = 0.154), and qualitative ranking (1.41 vs. 1.44, P = 0.21) for all vessels did not differ significantly between the two patient groups. The overall quality was good in 90.4% with gadoterate and 94.2% with gadobutrol (P = 0.462).
CONCLUSION: High-concentration gadobutrol allows neither a higher CNR nor any qualitative advantage over the ordinary unspecific Gd agent gadoterate when the same Gd load and injection times are used in multistation CE-MRA of the peripheral arteries. 2008 Wiley-Liss, Inc

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18504760     DOI: 10.1002/jmri.21351

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Dynamic contrast-enhanced MR imaging of the prostate: intraindividual comparison of gadoterate meglumine and gadobutrol.

Authors:  Chau Hung Lee; Balamurugan Vellayappan; Matthias Taupitz; Bernd Hamm; Patrick Asbach
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

2.  Prospective intraindividual comparison of gadoterate and gadobutrol for cervical and intracranial contrast-enhanced magnetic resonance angiography.

Authors:  Philip Hoelter; Stefan Lang; Marina Weibart; Manuel Schmidt; Michael F X Knott; Tobias Engelhorn; Marco Essig; Stephan Kloska; Arnd Doerfler
Journal:  Neuroradiology       Date:  2017-09-14       Impact factor: 2.804

3.  Enhancement characteristics and impact on image quality of two gadolinium chelates at equimolar doses for time-resolved 3-Tesla MR-angiography of the calf station.

Authors:  Jan Hansmann; Henrik J Michaely; John N Morelli; André Luckscheiter; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  PLoS One       Date:  2014-06-03       Impact factor: 3.240

4.  Gadobutrol Precedes Gd-DTPA in Abdominal Contrast-Enhanced MRA and MRI: A Prospective, Multicenter, Intraindividual Study.

Authors:  Xijiao Liu; Zhengyan Li; Weiwei Zhang; Caiwei Yang; Yike Diao; Ting Duan; Yu Fu; Jing Ren; Song Bin
Journal:  Contrast Media Mol Imaging       Date:  2019-12-02       Impact factor: 3.161