Literature DB >> 18502701

Multi-residue analysis of eight anticoagulant rodenticides in animal plasma and liver using liquid chromatography combined with heated electrospray ionization tandem mass spectrometry.

Virginie Vandenbroucke1, Noël Desmet, Patrick De Backer, Siska Croubels.   

Abstract

A sensitive method for the simultaneous quantification of eight anticoagulant rodenticides (brodifacoum, bromadiolone, chlorophacinone, coumatetralyl, difenacoum, difethialone, flocoumafen and warfarin) in animal plasma and liver using liquid chromatography combined with heated electrospray ionization tandem mass spectrometry (LC-HESI-MS/MS) is described. The sample preparation includes a liquid-liquid extraction with acetone. The compound 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin is used as an internal standard. Chromatographic separation was achieved using a Nucleodur C18 gravity column. Good linearity was observed up to 750 ng mL(-1) for chlorophacinone and up to 500 ng mL(-1) for the other compounds in plasma. In liver, good linearity was seen up to 500 ng g(-1) for brodifacoum, chlorophacinone, difenacoum and difethialone and up to 750 ng g(-1) for the other compounds. Depending on the compound, a level of 1 or 5 ng mL(-1) could be quantified fulfilling the criteria for accuracy and precision and was therefore set as limit of quantification of the method in plasma. In liver, the limit of quantification was set at 250 ng g(-1) for coumatetralyl and warfarin and at 100 ng g(-1) for the other compounds. In plasma, the limit of detection varied from 0.07 ng mL(-1) for flocoumafen to 3.21 ng mL(-1) for brodifacoum. In liver, the limit of detection varied from 0.37 ng g(-1) for warfarin to 4.64 ng g(-1) for chlorophacinone. The method was shown to be of use in a pharmacokinetic study after single oral administration to mice and in the confirmation of suspected poisoning cases in domestic animals.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18502701     DOI: 10.1016/j.jchromb.2008.05.011

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Detection of Brodifacoum and other Rodenticides in Drug Mixtures using Thermal Desorption Direct Analysis in Real Time Mass Spectrometry (TD-DART-MS).

Authors:  Elizabeth L Robinson; Edward Sisco
Journal:  J Forensic Sci       Date:  2018-12-10       Impact factor: 1.832

2.  Establishment and Validation of Anticoagulant Rodenticides in Animal Samples by HPLC-MS/MS, Focusing on Evaluating the Effect of Modified QuEChERS Protocol on Matrix Effect Reduction.

Authors:  Lei Zhu; Li Liu; Le Du; Jingmei Hao; Jianhua Ma; Jun Zhu; Wenjing Gong
Journal:  ACS Omega       Date:  2022-05-18

3.  Rapid, novel screening of toxicants in poison baits, and autopsy specimens by ambient mass spectrometry.

Authors:  Alessandra Tata; Ivana Pallante; Carmela Zacometti; Alessandra Moressa; Marco Bragolusi; Alessandro Negro; Andrea Massaro; Giovanni Binato; Federica Gallocchio; Roberto Angeletti; Nicola Pozzato; Roberto Piro
Journal:  Front Chem       Date:  2022-08-25       Impact factor: 5.545

4.  Separation and Quantification of Superwarfarin Rodenticide Diastereomers-Bromadiolone, Difenacoum, Flocoumafen, Brodifacoum, and Difethialone-in Human Plasma.

Authors:  Daniel G Nosal; Douglas L Feinstein; Luying Chen; Richard B van Breemen
Journal:  J AOAC Int       Date:  2020-06-01       Impact factor: 2.028

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.