Literature DB >> 18502083

Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: intermediate- and long-term outcomes.

Jose P Morales1, Roy K Greenberg, Catherine A Morales, Marcelo Cury, Adrian V Hernandez, Sean P Lyden, Daniel Clair.   

Abstract

OBJECTIVE: Little data exist to support the durability of thoracic endovascular repair during prolonged periods of follow-up. This study examines the durability and long-term results with the Zenith TX1 and TX2 thoracic devices (Cook Inc, Bloomington, Ind) in high-risk patients.
METHODS: Data were collected prospectively from 2001 to 2007 on high-risk patients who presented with thoracic aneurysms, chronic aortic dissection, or fistulas treated with a Zenith thoracic device. Surgical modifications of proximal or distal landing zones were performed when necessary. Computed tomography follow-up scans were performed before discharge, at 1, 6, and 12 months, and yearly thereafter. Three-dimensional reconstruction software with central line of flow measurements was used to assess aortic morphologic characteristics. Kaplan-Meier analysis was used to assess survival, freedom from reintervention, predictive factors of poor outcome, and morphologic changes, including aneurysm sac behavior.
RESULTS: A total of 160 patients (44% women; mean age, 70) were treated for 130 thoracic aneurysms, 25 aortic dissections with aneurysm, 2 fistulas, and 3 symptomatic or aortic ruptures, or both. Mean follow-up was 36 months, and aneurysm size was 67 mm. Seventy-five patients (47%) had undergone prior aortic aneurysm repair. Surgical modifications were required to create adequate landing zones in 33% patients, including 28 elephant trunk/arch reconstruction, 22 carotid-subclavian bypasses, and seven visceral vessel bypasses. Iliac conduits were required in 31 patients. Early mortality (<30 days) occurred in 11 patients (6.9%). Overall mortality at 1 year was 16%. Aneurysm sac increase (>5 mm) requiring intervention was observed only in one patient in the settings of component separation and type III endoleak that was treated; the sac is now stable. Twenty-seven endoleaks were detected in 25 patients: 15 primary endoleaks (9.4%) <30 days and 12 secondary endoleaks (7.5%) >30 days. Secondary interventions were required in 42 patients (26%).
CONCLUSION: Endovascular treatment of thoracic aortic pathologies with the Zenith TX1 and TX2 devices is feasible and durable. The mid- to long-term results are encouraging, with acceptable low reintervention rates and with good survival within high-risk patients.

Entities:  

Mesh:

Year:  2008        PMID: 18502083     DOI: 10.1016/j.jvs.2008.02.028

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  Endovascular stent grafts in urgent blunt and penetrating thoracic aortic trauma.

Authors:  Kenneth J Kolbeck; John A Kaufman
Journal:  Semin Intervent Radiol       Date:  2011-03       Impact factor: 1.513

2.  Safety of elective management of synchronous aortic disease with simultaneous thoracic and aortic stent graft placement.

Authors:  Salvatore T Scali; Robert J Feezor; Catherine K Chang; David H Stone; Philip P Goodney; Peter R Nelson; Thomas S Huber; Adam W Beck
Journal:  J Vasc Surg       Date:  2012-06-27       Impact factor: 4.268

3.  Long-term results of endovascular repair for distal arch and descending thoracic aortic aneurysms treated by custom-made endografts: usefulness of fenestrated endografts.

Authors:  Masakazu Matsuyama; Kunihide Nakamura; Hiroyuki Nagahama; Katsuhiko Nina; Jouji Endou; Kazushi Kojima; Masanori Nishimura; Hirohito Ishii; Atsuko Yokota
Journal:  Ann Vasc Dis       Date:  2014-12-25

4.  Thoracic Endovascular Aortic Repair Adverse Events Reported In The Food And Drug Administration Manufacturer And User Facility Device Experience Database.

Authors:  Neel A Mansukhani; Meraaj S Haleem; Mark K Eskandari
Journal:  Med Devices (Auckl)       Date:  2019-11-14

5.  Research and clinical translation of trilayer stent-graft of expanded polytetrafluoroethylene for interventional treatment of aortic dissection.

Authors:  Gang Wang; Caiyun Gao; Benhao Xiao; Jie Zhang; Xunyuan Jiang; Qunsong Wang; Jingzhen Guo; Deyuan Zhang; Jianxiong Liu; Yuehui Xie; Chang Shu; Jiandong Ding
Journal:  Regen Biomater       Date:  2022-07-22

6.  Stent-Graft Migration Post-Endovascular Repair of Thoracic Aorta: A Retrospective Cohort Study.

Authors:  Amit Ajit Deshpande; Niraj Nirmal Pandey; Manish Shaw; Sanjeev Kumar; Priya Jagia; Sanjiv Sharma; Shiv Choudhary
Journal:  Indian J Radiol Imaging       Date:  2022-07-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.