| Literature DB >> 18499610 |
Tina C Sichrovsky1, Suneet Mittal, Jonathan S Steinberg.
Abstract
Dexmedetomidine is frequently used for deep sedation during electrophysiology procedures. We report a case where, presumably, the use of dexmedetomidine resulted in a patient's death. The patient developed unexplained and refractory cardiogenic shock and could not be resuscitated. Autopsy failed to demonstrate any abnormality or cause of death. We postulate that, in certain susceptible individuals, dexmedetomidine may lead to terminal complications. We therefore urge caution about using dexmedetomidine in the electrophysiology laboratory.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18499610 DOI: 10.1213/ane.0b013e318172fafc