Abstract

PURPOSE: To compare the degree of visualization of the bile duct and portal vein in terms of the difference in k-space ordering on a three-dimensional (3D) segmented true fast imaging with steady-state precession (trueFISP) sequence.
MATERIALS AND METHODS: A breath-hold coronal 3D segmented trueFISP sequence was prospectively performed on 14 healthy volunteers. Images obtained with centric and linear k-space ordering in the k(x)-k(y) plane were compared by two independent radiologists qualitatively with depiction scores on a five-point scale (1=not seen to 5=excellent depiction) using the Wilcoxon signed-rank test. Images were also compared quantitatively using relative contrast values for the bile duct and portal vein against the hepatic parenchyma using a paired t-test.
RESULTS: With centric ordering, both the mean depiction scores and relative contrast values for the portal vein were significantly lower than those with linear ordering (1.5 vs. 3.5, P<.01; and 0.08+/-0.19 vs. 0.51+/-0.10, P<.01, respectively). However, in the bile duct, there were no significant differences, only slight differences were found among the results obtained with centric and linear ordering (3.9 vs. 3.8, P=.72; and 0.59+/-0.06 vs. 0.68+/-0.06, P<.01, respectively).
CONCLUSION: For visualizing the bile duct, centric k-space ordering on 3D segmented trueFISP sequence is recommended, while linear ordering is recommended for portal vein visualization.

Entities:  

Mesh:

Year:  2008        PMID: 18499383     DOI: 10.1016/j.mri.2008.03.003

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  2 in total

1.  Balanced Turbo Field Echo with Extended k-space Sampling: A Fast Technique for the Thoracic Ductography.

Authors:  Takakiyo Nomura; Tetsu Niwa; Toshiki Kazama; Tatsuya Sekiguchi; Takashi Okazaki; Shuhei Shibukawa; Hiroaki Nishio; Makoto Obara; Yutaka Imai
Journal:  Magn Reson Med Sci       Date:  2016-03-21       Impact factor: 2.471

2.  Visualization of Cerebrospinal Fluid Motion in the Whole Brain Using Three-dimensional Dynamic Improved Motion-sensitized Driven-equilibrium Steady-state Free Precession.

Authors:  Tomohiko Horie; Nao Kajihara; Haruo Saito; Shuhei Shibukawa; Makoto Obara; Tetsuo Ogino; Tetsu Niwa; Kagayaki Kuroda; Mitsunori Matsumae
Journal:  Magn Reson Med Sci       Date:  2020-03-18       Impact factor: 2.471

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.