Field testing a flow-through sampler for semivolatile organic compounds in air.

Hang Xiao1, Hayley Hung, Tom Harner, Ying D Lei, Frank Wania.   

Abstract

Even without access to the electrical grid, a flow-through sampler (FTS) can collect gaseous and particle-bound semivolatile organic compounds (SOCs) from large volumes of air by turning into the wind and having the wind blow through a porous sampling medium. To test its performance under field conditions, a FTS and a traditional pumped high volume air sampler, both using polyurethane foam (PUF) as sampling medium, were codeployed at the campus of the University of Toronto Scarborough from August 2006 to June 2007. Quantitative relationships between the wind speed outside the sampler and after passage through the PUF were established and allow the accurate estimation of sampling volumes under conditions of low and high wind speed. Polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) were quantified in the samples taken by both air samplers. Separate analysis of seven PUF disks arranged sequentially within the FTS, confirm that even relatively volatile SOCs do not experience serious break-through. Theoretical plate number analysis of the break-through curves yields an understanding of the effect of temperature and wind speed on FTS sampling efficiency, and reveals different behavior of gaseous and particle-bound-compounds on the PUF. Air concentrations of PCBs and PAHs obtained with the FTS compare favorably with those obtained by averaging the concentrations of several 24 h active high volume samples taken during the same time period.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18497152     DOI: 10.1021/es702741b

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  2 in total

1.  Latitudinal distribution of OCPs in the open ocean atmosphere between the Argentinian coast and Antarctic Peninsula.

Authors:  Guido Noé Rimondino; Ana Julieta Pepino; Martín Diego Manetti; Luis Olcese; Gustavo Alejandro Argüello
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-26       Impact factor: 4.223

2.  Passive air sampling for determining the levels of ambient PCDD/Fs and their seasonal and spatial variations and inhalation risk in Shanghai, China.

Authors:  Yajun Tian; Zhiqiang Nie; Shulei Tian; Feng Liu; Jie He; Yufei Yang; Xingrun Wang; Qingqi Die; Yanyan Fang; Qifei Huang
Journal:  Environ Sci Pollut Res Int       Date:  2015-05-05       Impact factor: 4.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.