OBJECTIVE: The optimal biphasic defibrillation dose for children is unknown. Postresuscitation myocardial dysfunction is common and may be worsened by higher defibrillation doses. Adult-dose automated external defibrillators are commonly available; pediatric doses can be delivered by attenuating the adult defibrillation dose through a pediatric pads/cable system. The objective was to investigate whether unattenuated (adult) dose biphasic defibrillation results in greater postresuscitation myocardial dysfunction and damage than attenuated (pediatric) defibrillation. DESIGN: Laboratory animal experiment. SETTING: University animal laboratory. SUBJECTS: Domestic swine weighing 19 +/- 3.6 kg. INTERVENTIONS: Fifty-two piglets were randomized to receive biphasic defibrillation using either adult-dose shocks of 200, 300, and 360 J or pediatric-dose shocks of approximately 50, 75, and 85 J after 7 mins of untreated ventricular fibrillation. Contrast left ventriculograms were obtained at baseline and then at 1, 2, 3, and 4 hrs postresuscitation. Postresuscitation left ventricular ejection fraction and cardiac troponins were evaluated. MEASUREMENTS AND MAIN RESULTS: By design, piglets in the adult-dose group received shocks with more energy (261 +/- 65 J vs. 72 +/- 12 J, p < .001) and higher peak current (37 +/- 8 A vs. 13 +/- 2 A, p < .001) at the largest defibrillation dose needed. In both groups, left ventricular ejection fraction was reduced significantly at 1, 2, and 4 hrs from baseline and improved during the 4 hrs postresuscitation. The decrease in left ventricular ejection fraction from baseline was greater after adult-dose defibrillation. Plasma cardiac troponin levels were elevated 4 hrs postresuscitation in 11 of 19 adult-dose piglets vs. four of 20 pediatric-dose piglets (p = .02). CONCLUSIONS: Unattenuated adult-dose defibrillation results in a greater frequency of myocardial damage and worse postresuscitation myocardial function than pediatric doses in a swine model of prolonged out-of-hospital pediatric ventricular fibrillation cardiac arrest. These data support the use of pediatric attenuating electrodes with adult biphasic automated external defibrillators to defibrillate children.
OBJECTIVE: The optimal biphasic defibrillation dose for children is unknown. Postresuscitation myocardial dysfunction is common and may be worsened by higher defibrillation doses. Adult-dose automated external defibrillators are commonly available; pediatric doses can be delivered by attenuating the adult defibrillation dose through a pediatric pads/cable system. The objective was to investigate whether unattenuated (adult) dose biphasic defibrillation results in greater postresuscitation myocardial dysfunction and damage than attenuated (pediatric) defibrillation. DESIGN: Laboratory animal experiment. SETTING: University animal laboratory. SUBJECTS: Domestic swine weighing 19 +/- 3.6 kg. INTERVENTIONS: Fifty-two piglets were randomized to receive biphasic defibrillation using either adult-dose shocks of 200, 300, and 360 J or pediatric-dose shocks of approximately 50, 75, and 85 J after 7 mins of untreated ventricular fibrillation. Contrast left ventriculograms were obtained at baseline and then at 1, 2, 3, and 4 hrs postresuscitation. Postresuscitation left ventricular ejection fraction and cardiac troponins were evaluated. MEASUREMENTS AND MAIN RESULTS: By design, piglets in the adult-dose group received shocks with more energy (261 +/- 65 J vs. 72 +/- 12 J, p < .001) and higher peak current (37 +/- 8 A vs. 13 +/- 2 A, p < .001) at the largest defibrillation dose needed. In both groups, left ventricular ejection fraction was reduced significantly at 1, 2, and 4 hrs from baseline and improved during the 4 hrs postresuscitation. The decrease in left ventricular ejection fraction from baseline was greater after adult-dose defibrillation. Plasma cardiac troponin levels were elevated 4 hrs postresuscitation in 11 of 19 adult-dose piglets vs. four of 20 pediatric-dose piglets (p = .02). CONCLUSIONS: Unattenuated adult-dose defibrillation results in a greater frequency of myocardial damage and worse postresuscitation myocardial function than pediatric doses in a swine model of prolonged out-of-hospital pediatric ventricular fibrillation cardiac arrest. These data support the use of pediatric attenuating electrodes with adult biphasic automated external defibrillators to defibrillate children.
Authors: Vinay M Nadkarni; Gregory Luke Larkin; Mary Ann Peberdy; Scott M Carey; William Kaye; Mary E Mancini; Graham Nichol; Tanya Lane-Truitt; Jerry Potts; Joseph P Ornato; Robert A Berg Journal: JAMA Date: 2006-01-04 Impact factor: 56.272
Authors: Marc D Berg; Ricardo A Samson; Robyn J Meyer; Lani L Clark; Terence D Valenzuela; Robert A Berg Journal: Resuscitation Date: 2005-10 Impact factor: 5.262
Authors: Giora Landesberg; Yellena Vesselov; Sharon Einav; Sergei Goodman; Charles L Sprung; Charles Weissman Journal: Crit Care Med Date: 2005-06 Impact factor: 7.598
Authors: C G Brown; D R Martin; P E Pepe; H Stueven; R O Cummins; E Gonzalez; M Jastremski Journal: N Engl J Med Date: 1992-10-08 Impact factor: 91.245
Authors: Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman Journal: Circulation Date: 2010-10-19 Impact factor: 29.690
Authors: Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman Journal: Pediatrics Date: 2010-10-18 Impact factor: 7.124
Authors: Dominik P Guensch; Janelle Yu; Gobinath Nadeshalingam; Kady Fischer; Jane Shearer; Matthias G Friedrich Journal: PLoS One Date: 2016-09-09 Impact factor: 3.240