Literature DB >> 18496348

Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate.

Mario Loeffel1, Stephen J Ferguson, Lutz-P Nolte, Jens H Kowal.   

Abstract

STUDY
DESIGN: This is an experimental study on an artificial vertebra model and human cadaveric spine.
OBJECTIVE: Characterization of polymethylmethacrylate (PMMA) bone cement distribution in the vertebral body as a function of cement viscosity, bone porosity, and injection speed. Identification of relevant parameters for improved cement flow predictability and leak prevention in vertebroplasty. SUMMARY OF BACKGROUND DATA: Vertebroplasty is an efficient procedure to treat vertebral fractures and stabilize osteoporotic bone in the spine. Severe complications result from bone cement leakage into the spinal canal or the vascular system. Cement viscosity has been identified as an important parameter for leak prevention but the influence of bone structure and injection speed remain obscure.
METHODS: An artificial vertebra model based on open porous aluminum foam was used to simulate bone of known porosity. Fifty-six vertebroplasties with 4 different starting viscosity levels and 2 different injection speeds were performed on artificial vertebrae of 3 different porosities. A validation on a human cadaveric spine was executed. The experiments were radiographically monitored and the shape of the cement clouds quantitatively described with the 2 indicators circularity and mean cement spreading distance.
RESULTS: An increase in circularity and a decrease in mean cement spreading distance was observed with increasing viscosity, with the most striking change occurring between 50 and 100 Pas. Larger pores resulted in significantly reduced circularity and increased mean cement spreading distance whereas the effect of injection speed on the 2 indicators was not significant.
CONCLUSION: Viscosity is the key factor for reducing the risk of PMMA cement leakage and it should be adapted to the degree of osteoporosis encountered in each patient. It may be advisable to opt for a higher starting viscosity but to inject the material at a faster rate.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18496348     DOI: 10.1097/BRS.0b013e3181732aa9

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  32 in total

1.  Vertebroplasty and balloon kyphoplasty in osteoporosis: friends or foes?

Authors:  Gemma Marcucci; Maria Luisa Brandi
Journal:  Clin Cases Miner Bone Metab       Date:  2009-09

2.  Subject-specific planning of femoroplasty: a combined evolutionary optimization and particle diffusion model approach.

Authors:  Ehsan Basafa; Mehran Armand
Journal:  J Biomech       Date:  2014-05-14       Impact factor: 2.712

3.  Direct and interactive effects of three variables on properties of PMMA bone cement for vertebral body augmentation.

Authors:  Alejandro López; Erik Unosson; Håkan Engqvist; Cecilia Persson
Journal:  J Mater Sci Mater Med       Date:  2011-04-28       Impact factor: 3.896

4.  Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients.

Authors:  Si-Yuan Zhu; Zhao-Ming Zhong; Qian Wu; Jian-Ting Chen
Journal:  Int Orthop       Date:  2016-01-12       Impact factor: 3.075

5.  Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures.

Authors:  Jie Ding; Qiong Zhang; Jianfei Zhu; Weiwei Tao; Qi Wu; Lu Chen; Pengwen Shi; Haojie Zhang
Journal:  Eur Spine J       Date:  2015-04-08       Impact factor: 3.134

6.  The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws.

Authors:  Hui-Zhi Guo; Yong-Chao Tang; Dan-Qing Guo; Shun-Cong Zhang; Yong-Xian Li; Guo-Ye Mo; Pei-Jie Luo; Ten-Peng Zhou; Yan-Huai Ma; Xiao-Bing Jiang
Journal:  Eur Spine J       Date:  2019-04-27       Impact factor: 3.134

7.  Cement-augmented screws in a cervical two-level corpectomy with anterior titanium mesh cage reconstruction: a biomechanical study.

Authors:  Sebastian Hartmann; Claudius Thomé; Anja Tschugg; Johannes Paesold; Pujan Kavakebi; Werner Schmölz
Journal:  Eur Spine J       Date:  2017-01-21       Impact factor: 3.134

8.  Intravertebral pressure gradient during vertebroplasty.

Authors:  Markus Weisskopf; Oliver Miltner; Uwe Maus; Sascha Gravius; Jörg Axel Karl Ohnsorge
Journal:  Skeletal Radiol       Date:  2012-06-09       Impact factor: 2.199

9.  Mechanical properties of blood-mixed polymethylmetacrylate in percutaneous vertebroplasty.

Authors:  Dong Ki Ahn; Song Lee; Dea Jung Choi; Soon Yeol Park; Dae Gon Woo; Chi Hoon Kim; Han Sung Kim
Journal:  Asian Spine J       Date:  2009-12-31

10.  Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.

Authors:  Jin Luo; Michael A Adams; Patricia Dolan
Journal:  J Osteoporos       Date:  2010-06-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.