Literature DB >> 18495468

Highly specific label-free protein detection from lysed cells using internally referenced microcantilever sensors.

Wenmiao Shu1, Sophie Laurenson, Tuomas P J Knowles, Paul Ko Ferrigno, Ashwin A Seshia.   

Abstract

We report the investigation of label-free protein detection directly from lysed cells using microcantilever sensors. The integration of an internally referenced microcantilever sensor combined with peptide aptamer technology enables scalable and label-free detection of proteins from a complex biological environment (e.g. cell lysate). The internally referenced microcantilever sensor was found to be effective in minimizing both the effects of thermal drift and non-specific binding interactions with the backside of the cantilever, thereby allowing protein detection in a complex biological background. Highly specific peptide aptamers are used to modify the cantilever surface to specifically detect less than 80 nM CDK2 protein from yeast cell lysate. This binding of CDK2 on the microcantilever generates a tensile surface stress of average magnitude equal to 70+/-22 mN/m. Similar experiments conducted with quartz crystal microbalance (QCM) technology are consistent with the response observed using microcantilever sensors.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18495468     DOI: 10.1016/j.bios.2008.03.036

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Aptamer-based fluorescent biosensors.

Authors:  R E Wang; Y Zhang; J Cai; W Cai; T Gao
Journal:  Curr Med Chem       Date:  2011       Impact factor: 4.530

2.  Folding-based electrochemical biosensors: the case for responsive nucleic acid architectures.

Authors:  Arica A Lubin; Kevin W Plaxco
Journal:  Acc Chem Res       Date:  2010-04-20       Impact factor: 22.384

Review 3.  Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors.

Authors:  Hai-Feng Ji; Benjamin D Armon
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

4.  Structure-function studies of an engineered scaffold protein derived from stefin A. I: Development of the SQM variant.

Authors:  Toni Hoffmann; Lukas Kurt Josef Stadler; Michael Busby; Qifeng Song; Anthony T Buxton; Simon D Wagner; Jason J Davis; Paul Ko Ferrigno
Journal:  Protein Eng Des Sel       Date:  2010-02-23       Impact factor: 1.650

Review 5.  Hybrid integrated label-free chemical and biological sensors.

Authors:  Simin Mehrabani; Ashley J Maker; Andrea M Armani
Journal:  Sensors (Basel)       Date:  2014-03-26       Impact factor: 3.576

6.  A self-sensing piezoelectric microcantilever biosensor for detection of ultrasmall adsorbed masses: theory and experiments.

Authors:  Samira Faegh; Nader Jalili; Srinivas Sridhar
Journal:  Sensors (Basel)       Date:  2013-05-10       Impact factor: 3.576

Review 7.  Non-antibody protein-based biosensors.

Authors:  Paul Ko Ferrigno
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.