Literature DB >> 18495387

Mammographic density using two computer-based methods in an isoflavone trial.

Masako Kataoka1, Charlotte Atkinson, Ruth Warren, Evis Sala, Nicholas E Day, Ralph Highnam, Iqbal Warsi, Sheila A Bingham.   

Abstract

OBJECTIVES: Mammographic density is a useful biomarker of breast cancer risk. Computer-based methods can provide continuous data suitable for analysis. This study aimed to compare a semi-automated computer-assisted method (Cumulus) and a fully automated volumetric computer method (standard mammogram form (SMF)) for assessing mammographic density using data from a previously conducted randomised placebo-controlled trial of an isoflavone supplement.
METHODS: Mammograms were obtained from participants in the intervention study. A total of 177 women completed the study. Baseline and follow-up mammograms were digitised and density was estimated using Cumulus (read by two readers) and SMF. Left-right correlation, changes in density over time, and difference between intervention and control groups were evaluated. Changes of density over time, and changes between intervention group and control group were examined using paired t-test and Student's t-test, respectively.
RESULTS: Inter-reader correlation coefficient by Cumulus was 0.90 for dense area, and 0.86 for percentage density. Left-right correlation of percent density was lower in SMF than in Cumulus. Among all women, percentage density by Cumulus decreased significantly over time, but no change was seen for SMF percentage density. The intervention group showed marginally significant greater reduction of percent density by Cumulus compared to controls (p=0.04), but the difference became weak after adjustment for baseline percent density (p=0.06). No other measurement demonstrated significant difference between intervention and control groups.
CONCLUSIONS: This comparison suggests that slightly different conclusions could be drawn from different methods used to assess breast density. The development of a more robust fully automated method is awaited.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18495387     DOI: 10.1016/j.maturitas.2008.03.005

Source DB:  PubMed          Journal:  Maturitas        ISSN: 0378-5122            Impact factor:   4.342


  7 in total

1.  Isoflavones - Mechanism of Action and Impact on Breast Cancer Risk.

Authors:  Johannes Stubert; Bernd Gerber
Journal:  Breast Care (Basel)       Date:  2009-02-20       Impact factor: 2.860

2.  Comparison of breast density measured by dual energy X-ray absorptiometry with mammographic density among adult women in Hawaii.

Authors:  Gertraud Maskarinec; Yukiko Morimoto; Yihe Daida; Aurelie Laidevant; Serghei Malkov; John A Shepherd; Rachel Novotny
Journal:  Cancer Epidemiol       Date:  2010-08-04       Impact factor: 2.984

3.  Habitual Phytoestrogen Intake Is Associated with Breast Composition in Girls at 2 Years after Menarche Onset.

Authors:  Constanza Lesser; Verónica Mericq; Marcela Reyes; María Luisa Garmendia; John A Shepherd; Karin B Michels; Camila Corvalán; Ana Pereira
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2022-07-01       Impact factor: 4.090

Review 4.  Effects of isoflavones on breast density in pre- and post-menopausal women: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Lee Hooper; Giri Madhavan; Jeffrey A Tice; Sam J Leinster; Aedín Cassidy
Journal:  Hum Reprod Update       Date:  2010-05-28       Impact factor: 15.610

Review 5.  Epidemiologic studies of isoflavones & mammographic density.

Authors:  Gertraud Maskarinec; Martijn Verheus; Jeffrey A Tice
Journal:  Nutrients       Date:  2010-01-19       Impact factor: 5.717

Review 6.  Soy, red clover, and isoflavones and breast cancer: a systematic review.

Authors:  Heidi Fritz; Dugald Seely; Gillian Flower; Becky Skidmore; Rochelle Fernandes; Sarah Vadeboncoeur; Deborah Kennedy; Kieran Cooley; Raimond Wong; Stephen Sagar; Elham Sabri; Dean Fergusson
Journal:  PLoS One       Date:  2013-11-28       Impact factor: 3.240

7.  Reliability of the percent density in digital mammography with a semi-automated thresholding method.

Authors:  Guiyun Sohn; Jong Won Lee; Sung Won Park; Jihoon Park; Jiyoung Woo; Hwa Jung Kim; Hee Jung Shin; Hak Hee Kim; Kyung Hae Jung; Joohon Sung; Seung Wook Lee; Byung Ho Son; Sei-Hyun Ahn
Journal:  J Breast Cancer       Date:  2014-06-27       Impact factor: 3.588

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.