Literature DB >> 18495135

High performance liquid chromatography coupled on-line to capillary electrophoresis with laser-induced fluorescence detection for detecting inhibitors of Src homology 2 domain-phosphopeptide binding in mixtures.

Peilin Yang1, Robert T Kennedy.   

Abstract

Reversed-phase HPLC was coupled on-line to a rapid, competitive affinity probe capillary electrophoresis (APCE) assay to screen mixtures for compounds that inhibit protein-ligand interactions. The Fyn Src homology 2 (SH2) domain and its phosphopeptide binding partner were used as a model interaction for demonstration of this technique. In the method, mixtures containing possible inhibitors of binding were separated by HPLC at a flow rate of 0.3 mL/min. A small portion of effluent was directed to a fluidic tee where it was mixed on-line with Fyn SH2 domain and a fluorescent phosphopeptide ("affinity probe") known to bind selectively to Fyn SH2 domain. Electropherograms of the reaction mixture were collected on-line at approximately 6s intervals using a flow-gated interface to control injections onto the capillary electrophoresis with laser-induced fluorescence system. The resulting electropherograms contained two peaks, one corresponding to the free affinity probe and the other a complex of the affinity probe and Fyn SH2 domain. Compounds that bound the protein were detected as a decrease in the peak height of the complex and an increase in the peak height of affinity probe with relative standard deviations of <5%. The assay was shown to resolve multiple peptidergic inhibitors and selectively detect them within a complex mixture of peptides. Signals were dependent upon both concentration of active peptide and its potency in binding inhibition. Detection limits were in the range of 2-11 microM depending upon the peptide. Common organic solvents used in HPLC were shown to have minimal effect in the on-line measurement up to approximately 60% in the mobile phase.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18495135     DOI: 10.1016/j.chroma.2008.04.072

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Prototyping of poly(dimethylsiloxane) interfaces for flow gating, reagent mixing, and tubing connection in capillary electrophoresis.

Authors:  Qiyang Zhang; Maojun Gong
Journal:  J Chromatogr A       Date:  2013-11-28       Impact factor: 4.759

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.