Literature DB >> 18494743

Self-application of single-use eyedrop containers in an elderly population: comparisons with standard eyedrop bottle and with younger patients.

Thomas S Dietlein1, Jens F Jordan, Christoph Lüke, Andrea Schild, Sven Dinslage, Guenter K Krieglstein.   

Abstract

PURPOSE: To test whether patients aged >or=80 years can safely and successfully apply eyedrops from a single-use eyedrop container without support, and to compare the results with those of younger patients using single-use containers and older patients using standard eyedrop bottles.
METHODS: Patients aged >or=80 years who had no physical or mental conditions hindering self-application of eyedrops and actually did so because of glaucoma or dry eyes were included consecutively in the study group (n = 44) in order to perform self-application of eyedrops from single-use eyedrop containers. Patients were observed meticulously by two investigators, who documented practical problems during the procedure in a checklist. In control group A (n = 22), glaucoma or sicca patients aged between 50 and 65 years applied drops from single-use eyedrop containers; in control group B (n = 28), glaucoma or sicca patients aged >or=80 years used a traditional eyedrop bottle.
RESULTS: Successful application of the drops into the conjunctival sac was achieved by 57% in the study group (95% and 89% in control groups A and B, respectively). Scratching of the eyedrop container along the conjunctiva or cornea was observed in 68% of the study group (41% and 61% in control groups A and B, respectively). Frequency of problems during opening and self-application of single-use eyedrop containers in the study group showed an inverse correlation to visual acuity in the better eye and previous experience with this kind of eyedrop container.
CONCLUSION: Older patients have massive problems in self-administering eyedrops from single-use containers. Factors influencing the success of self-application may include the patient's previous experience with this kind of eyedrop container and the patient's visual acuity.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18494743     DOI: 10.1111/j.1755-3768.2007.01155.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  22 in total

1.  Irreversible electroporation for microbial control of drugs in solution.

Authors:  Alex Golberg; Michael Belkin; Boris Rubinsky
Journal:  AAPS PharmSciTech       Date:  2009-07-02       Impact factor: 3.246

2.  [Minimally invasive iridocorneal angle surgery].

Authors:  J F Jordan
Journal:  Ophthalmologe       Date:  2012-07       Impact factor: 1.059

3.  [Current developments in minimally invasive glaucoma surgery].

Authors:  C Erb
Journal:  Ophthalmologe       Date:  2018-05       Impact factor: 1.059

4.  Handling test of eye drop dispenser--comparison of unit-dose pipettes with conventional eye drop bottles.

Authors:  Minna Parkkari; Terho Latvala; Auli Ropo
Journal:  J Ocul Pharmacol Ther       Date:  2010-06       Impact factor: 2.671

5.  [Pharmaceutical aids in gerontopharmacology].

Authors:  W Kircher
Journal:  Internist (Berl)       Date:  2013-01       Impact factor: 0.743

Review 6.  Preservative-Free Prostaglandin Analogs and Prostaglandin/Timolol Fixed Combinations in the Treatment of Glaucoma: Efficacy, Safety and Potential Advantages.

Authors:  Gábor Holló; Andreas Katsanos; Kostas G Boboridis; Murat Irkec; Anastasios G P Konstas
Journal:  Drugs       Date:  2018-01       Impact factor: 9.546

7.  Eye drop instillation technique in patients with glaucoma.

Authors:  A J Tatham; U Sarodia; F Gatrad; A Awan
Journal:  Eye (Lond)       Date:  2013-08-23       Impact factor: 3.775

Review 8.  Drop-free approaches for cataract surgery.

Authors:  Neal H Shorstein; William G Myers
Journal:  Curr Opin Ophthalmol       Date:  2020-01       Impact factor: 4.299

9.  Single subconjunctival injection formulation using sol-gel mesoporous silica as a controlled release system for drop-free post-cataract surgery care.

Authors:  Yaoyao Sun; Kristyn Huffman; William R Freeman; Lingyun Cheng
Journal:  J Cataract Refract Surg       Date:  2020-11       Impact factor: 3.528

10.  Impact of patient access to Internet health records on glaucoma medication: randomized controlled trial.

Authors:  Kenji Kashiwagi; Shigeo Tsukahara
Journal:  J Med Internet Res       Date:  2014-01-15       Impact factor: 5.428