Heart rate response to hemorrhage-induced 0.05-Hz oscillations in arterial pressure in conscious dogs.

J B Madwed1, R J Cohen.   

Abstract

We have previously reported that oscillations at 0.05 Hz can be generated by a simple computer model incorporating a negative-feedback reflex mechanism and an effector mechanism with a time delay. Computer simulations by inhibiting the vagal effector mechanism and activating the adrenergic effector mechanism elicited low-frequency oscillations at a frequency of 0.05 Hz in heart rate. We have observed that the cardiovascular system of the conscious dog, when stressed by the loss of blood, generates oscillations in arterial pressure and heart rate at a frequency of 0.05 Hz. We investigated in six conscious dogs the role of the sympathetic and parasympathetic nervous systems in generating these heart rate oscillations. During baseline conditions, the predominant peak in the arterial pressure and heart rate power spectra was located at the respiratory frequency, while the low-frequency oscillations were small. After a 30-ml/kg hemorrhage or after an 8-, 15-, or 30-ml/kg hemorrhage with glycopyrrolate, a muscarinic-blocking agent, low-frequency oscillations at a frequency of 0.05 Hz predominated, while the respiratory frequency oscillations were negligible. Since respiratory frequency oscillations have been reported to reflect vagal activity, and since the low-frequency oscillations were present after vagal blockade, these hemorrhage-induced low-frequency oscillations in heart rate may be primarily mediated by the cardiac sympathetic nerves. Also cross-correlation analysis between arterial pressure and heart rate showed that a change in arterial pressure caused an opposite change in heart rate with a delay of 2-5 s. We conclude that hemorrhage-induced oscillations in heart rate at 0.05 Hz represent the arterial baroreceptor-beta-sympathetic reflex response to underlying arterial pressure oscillations.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1849372     DOI: 10.1152/ajpheart.1991.260.4.H1248

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  6 in total

1.  Effects of plasmapheresis on short-term variability of blood pressure in healthy donors.

Authors:  A Girard; M L Phan; F Weise; J L Elghozi
Journal:  Clin Auton Res       Date:  1992-10       Impact factor: 4.435

2.  High-resolution estimation of the heart rate variability signal.

Authors:  T Harel; I Gath; S Ben-Haim
Journal:  Med Biol Eng Comput       Date:  1997-01       Impact factor: 2.602

3.  A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome.

Authors:  T Matsui; I Arai; S Gotoh; H Hattori; B Takase; M Kikuchi; M Ishihara
Journal:  Biomed Pharmacother       Date:  2005-10       Impact factor: 6.529

4.  Spectral indices of cardiovascular adaptations to short-term simulated microgravity exposure.

Authors:  A R Patwardhan; J M Evans; M Berk; K J Grande; J B Charles; C F Knapp
Journal:  Integr Physiol Behav Sci       Date:  1995 Jul-Sep

5.  The effect of severe brainstem injury on heart rate and blood pressure oscillations.

Authors:  V Novak; P Novak; M deMarchie; R Schondorf
Journal:  Clin Auton Res       Date:  1995-02       Impact factor: 4.435

6.  Vasovagal oscillations and vasovagal responses produced by the vestibulo-sympathetic reflex in the rat.

Authors:  Sergei B Yakushin; Giorgio P Martinelli; Theodore Raphan; Yongqing Xiang; Gay R Holstein; Bernard Cohen
Journal:  Front Neurol       Date:  2014-04-04       Impact factor: 4.003