Literature DB >> 18492877

CT angiography in suspected pulmonary embolism: impact of patient characteristics and different venous lines on vessel enhancement and image quality.

Daniela Roggenland1, Soeren A Peters, Stefan P Lemburg, Tim Holland-Letz, Volkmar Nicolas, Christoph M Heyer.   

Abstract

OBJECTIVE: The objective of our study was to compare image quality, patient characteristics, and different catheters in pulmonary CT angiography (CTA) performed with bolus tracking and z-axis automated tube current modulation (ATCM) in patients with suspected pulmonary embolism. SUBJECTS AND METHODS: One hundred twenty-six patients were referred to undergo pulmonary CTA with bolus tracking and ATCM. Besides patient characteristics, the type, position, size, and side of venous catheters were documented. Pulmonary vessel enhancement and image noise were quantified; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective vessel contrast was assessed by two radiologists in consensus.
RESULTS: Patient age showed a moderate but significant positive correlation to vessel enhancement (r = 0.244, p = 0.006), CNR (r = 0.178, p = 0.046), and subjective image quality (r = 0.344, p < 0.001). Patient weight revealed a significant negative correlation to vessel enhancement (r = -0.496, p < 0.001), SNR (r = -0.446, p < 0.001), CNR (r = -0.425, p < 0.001), and subjective image quality (r = -0.422, p < 0.001). In univariate analysis, SNR and CNR were significantly higher in patients who received contrast medium through peripheral catheters (30 +/- 13 and 27 +/- 13, respectively) than in those in whom central catheters were used (22 +/- 8 and 19 +/- 7, p = 0.041 and p = 0.029, respectively). Neither patient sex nor catheter size, position, or side had any significant impact on image quality.
CONCLUSION: Patient age and weight showed significant impact on vascular attenuation and image quality in pulmonary CTA with bolus tracking and ATCM, whereas patient sex and different peripheral catheters did not significantly influence image parameters.

Entities:  

Mesh:

Year:  2008        PMID: 18492877     DOI: 10.2214/AJR.07.3402

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

2.  Multidetector-CT angiography in pulmonary embolism-can image parameters predict clinical outcome?

Authors:  Christoph M Heyer; Stefan P Lemburg; Heiko Knoop; Tim Holland-Letz; Volkmar Nicolas; Daniela Roggenland
Journal:  Eur Radiol       Date:  2011-04-11       Impact factor: 5.315

Review 3.  Imaging of suspected pulmonary embolism and deep venous thrombosis in obese patients.

Authors:  Vincent Cascio; Man Hon; Linda B Haramati; Animesh Gour; Peter Spiegler; Sanjeev Bhalla; Douglas S Katz
Journal:  Br J Radiol       Date:  2018-06-27       Impact factor: 3.039

4.  Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients.

Authors:  Zsolt Szucs-Farkas; Tamara Strautz; Michael A Patak; Luzia Kurmann; Peter Vock; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2009-03-31       Impact factor: 5.315

5.  Computed tomography pulmonary angiography using a 20% reduction in contrast medium dose delivered in a multiphasic injection.

Authors:  Mitchell Chen; Gaith Mattar; Jamal A Abdulkarim
Journal:  World J Radiol       Date:  2017-03-28

6.  Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism.

Authors:  Xuemei Hu; Liya Ma; Jinhua Zhang; Zhen Li; Yaqi Shen; Daoyu Hu
Journal:  Sci Rep       Date:  2017-10-16       Impact factor: 4.379

7.  Arterial attenuation in individualized computed tomography pulmonary angiography injection protocol adjusted based on the patient's body mass index.

Authors:  Leila Jamali; Babak Alikhani; Tobias Getzin; Kristina Imeen Ringe; Frank K Wacker; Hans-Jürgen Raatschen
Journal:  J Res Med Sci       Date:  2020-10-28       Impact factor: 1.852

8.  Diagnostic yield of CT thorax angiography in patients suspected of pulmonary embolism: independent predictors and protocol adherence.

Authors:  Stefan Walen; Minke-Alie Leijstra; Steven M Uil; Martijn F Boomsma; Jan Willem K van den Berg
Journal:  Insights Imaging       Date:  2014-04-03

9.  Patient body weight-tailored contrast medium injection protocol for the craniocervical vessels: a prospective computed tomography study.

Authors:  Rebecca Kessler; Katrin Hegenscheid; Steffen Fleck; Alexander Khaw; Michael Kirsch; Norbert Hosten; Sönke Langner
Journal:  PLoS One       Date:  2014-02-18       Impact factor: 3.240

10.  Prospective Study of Low-Radiation and Low-Iodine Dose Aortic CT Angiography in Obese and Non-Obese Patients: Image Quality and Impact of Patient Characteristics.

Authors:  Matthias A Fink; Sibylle Stoll; Claudius Melzig; Andrea Steuwe; Sasan Partovi; Dittmar Böckler; Hans-Ulrich Kauczor; Fabian Rengier
Journal:  Diagnostics (Basel)       Date:  2022-03-10
View more