Literature DB >> 18492876

Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets.

Bohyoung Kim1, Kyoung Ho Lee, Kil Joong Kim, Rafal Mantiuk, Hye-ri Kim, Young Hoon Kim.   

Abstract

OBJECTIVE: The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images.
MATERIALS AND METHODS: At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used.
RESULTS: At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001).
CONCLUSION: Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.

Mesh:

Year:  2008        PMID: 18492876     DOI: 10.2214/AJR.07.3405

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Computed Tomography Image Compressibility and Limitations of Compression Ratio-Based Guidelines.

Authors:  Jean-François Pambrun; Rita Noumeir
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

2.  Development of an algorithm to automatically compress a CT image to visually lossless threshold.

Authors:  Chang-Mo Nam; Kyong Joon Lee; Yousun Ko; Kil Joong Kim; Bohyoung Kim; Kyoung Ho Lee
Journal:  BMC Med Imaging       Date:  2018-12-17       Impact factor: 1.930

3.  LOCAT (low-dose computed tomography for appendicitis trial) comparing clinical outcomes following low- vs standard-dose computed tomography as the first-line imaging test in adolescents and young adults with suspected acute appendicitis: study protocol for a randomized controlled trial.

Authors:  Soyeon Ahn
Journal:  Trials       Date:  2014-01-17       Impact factor: 2.279

  3 in total