Literature DB >> 18492509

Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room.

C Omar F Kamlin1, Jennifer A Dawson, Colm P F O'Donnell, Colin J Morley, Susan M Donath, Jasbir Sekhon, Peter G Davis.   

Abstract

OBJECTIVE: To determine the accuracy of heart rate obtained by pulse oximetry (HR(PO)) relative to HR obtained by 3-lead electrocardiography (HR(ECG)) in newborn infants in the delivery room. STUDY
DESIGN: Immediately after birth, a preductal PO sensor and ECG leads were applied. PO and ECG monitor displays were recorded by a video camera. Two investigators reviewed the videos. Every two seconds, 1 of the investigators recorded HR(PO) and indicators of signal quality from the oximeter while masked to ECG, whereas the other recorded HR(ECG) and ECG signal quality while masked to PO. HR(PO) and HR(ECG) measurements were compared using Bland-Altman analysis.
RESULTS: We attended 92 deliveries; 37 infants were excluded due to equipment malfunction. The 55 infants studied had a mean (+/-standard deviation [SD]) gestational age of 35 (+/-3.7) weeks, and birth weight 2399 (+/-869) g. In total, we analyzed 5877 data pairs. The mean difference (+/-2 SD) between HR(ECG) and HR(PO) was -2 (+/-26) beats per minute (bpm) overall and -0.5 (+/-16) bpm in those infants who received positive-pressure ventilation and/or cardiac massage. The sensitivity and specificity of PO for detecting HR(ECG) <100 bpm was 89% and 99%, respectively.
CONCLUSION: PO provided an accurate display of newborn infants' HR in the delivery room, including those infants receiving advanced resuscitation.

Entities:  

Mesh:

Year:  2008        PMID: 18492509     DOI: 10.1016/j.jpeds.2008.01.002

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  23 in total

1.  Physiological and behavioral responses reveal 9-month-old infants' sensitivity to pleasant touch.

Authors:  Merle T Fairhurst; Line Löken; Tobias Grossmann
Journal:  Psychol Sci       Date:  2014-03-28

2.  Singapore Neonatal Resuscitation Guidelines 2016.

Authors:  Cheo Lian Yeo; Agnihotri Biswas; Teong Tai Kenny Ee; Amutha Chinnadurai; Vijayendra Ranjan Baral; Alvin Shang Ming Chang; Imelda Lustestica Ereno; Kah Ying Selina Ho; Woei Bing Poon; Varsha Atul Shah; Bin Huey Quek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

3.  The role of pulse oximetry in chiropractic practice: a rationale for its use.

Authors:  Michael W Hall; Anne M Jensen
Journal:  J Chiropr Med       Date:  2012-06

Review 4.  Oxygen saturation and heart rate in healthy term and late preterm infants with delayed cord clamping.

Authors:  Inmaculada Lara-Cantón; Shiraz Badurdeen; Janneke Dekker; Peter Davis; Calum Roberts; Arjan Te Pas; Máximo Vento
Journal:  Pediatr Res       Date:  2022-01-07       Impact factor: 3.756

5.  Avoiding hyperoxemia during neonatal resuscitation: time to response of different SpO2 monitors.

Authors:  Hernando Baquero; Ramiro Alviz; Armando Castillo; Fredy Neira; Augusto Sola
Journal:  Acta Paediatr       Date:  2011-01-17       Impact factor: 2.299

6.  Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

Authors:  Graeme R Polglase; Jennifer A Dawson; Martin Kluckow; Andrew W Gill; Peter G Davis; Arjan B Te Pas; Kelly J Crossley; Annie McDougall; Euan M Wallace; Stuart B Hooper
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

7.  Noninvasive Monitoring during Interhospital Transport of Newborn Infants.

Authors:  Georg M Schmölzer; Megan O'Reilly; Po-Yin Cheung
Journal:  Crit Care Res Pract       Date:  2013-02-24

Review 8.  Delivery room handling of the newborn.

Authors:  Stephanie Marshall; Astri Maria Lang; Marta Perez; Ola D Saugstad
Journal:  J Perinat Med       Date:  2019-12-18       Impact factor: 2.716

Review 9.  [Newborn resuscitation and support of transition of infants at birth].

Authors:  John Madar; Charles C Roehr; Sean Ainsworth; Hege Ersda; Colin Morley; Mario Rüdiger; Christiane Skåre; Tomasz Szczapa; Arjan Te Pas; Daniele Trevisanuto; Berndt Urlesberger; Dominic Wilkinson; Jonathan P Wyllie
Journal:  Notf Rett Med       Date:  2021-06-02       Impact factor: 0.892

10.  Evaluation of Heart Rate Assessment Timing, Communication, Accuracy, and Clinical Decision-Making during High Fidelity Simulation of Neonatal Resuscitation.

Authors:  Win Boon; Jennifer McAllister; Mohammad A Attar; Rachel L Chapman; Patricia B Mullan; Hilary M Haftel
Journal:  Int J Pediatr       Date:  2014-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.