Literature DB >> 18492085

Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems.

Jörg Ruppin1, Aleksandra Popovic, Mario Strauss, Elmar Spüntrup, Alexander Steiner, Christian Stoll.   

Abstract

OBJECTIVES: In dental implant surgery, computer-aided surgery (CAS) techniques can provide a high medical benefit. Two different techniques are established for transferring a CAS treatment planning to the patient: the use of surgical templates (splints) or intraoperative navigation using optical tracking. The aim of this study was to evaluate the total application accuracy of three different CAS systems (Artma virtual patient, RoboDent LapAccedo, Materialise SurgiGuide): two featuring optical tracking, one featuring stereolithographically manufactured splints.
MATERIALS AND METHODS: A total of 120 implants were placed into 20 human cadaver mandibles. Preoperative computed tomography (CT) scans imported to the corresponding software were used to plan the implant positions on the computer. Implant placement was performed using either optical tracking or stereolithographic splints. Postoperative CT scans were used to obtain the achieved implant positions. A semi-automatic approach was developed to compare planned and achieved implant positions. Deviations between planned and achieved positions were measured for each implant in position (Delta xy), depth (Delta z) and axis (Delta phi).
CONCLUSION: Despite the different techniques of transfer, no statistically significant differences were found between all groups. The accuracy achieved corresponded well with the spatial resolution of the CT Scans used.

Entities:  

Mesh:

Year:  2008        PMID: 18492085     DOI: 10.1111/j.1600-0501.2007.01430.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

1.  Fabrication of a surgical guide with help of a milling machine by ridge mapping method.

Authors:  Seema Pattanaik; Bikash K Pattanaik
Journal:  J Indian Prosthodont Soc       Date:  2012-10-30

2.  The Single-tooth Implant Treatment of Congenitally Missing Maxillary Lateral Incisors Using Angled Abutments: A Clinical Report.

Authors:  Suleyman Hakan Tuna; Filiz Keyf; Gurel Pekkan
Journal:  Dent Res J (Isfahan)       Date:  2009

Review 3.  Computerized implant-dentistry: Advances toward automation.

Authors:  Minkle Gulati; Vishal Anand; Sanjeev Kumar Salaria; Nikil Jain; Shilpi Gupta
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

Review 4.  Rapid prototyping and stereolithography in dentistry.

Authors:  Sanjna Nayar; S Bhuminathan; Wasim Manzoor Bhat
Journal:  J Pharm Bioallied Sci       Date:  2015-04

5.  Computer-aided design provisionalization and implant insertion combined with optical scanning of plaster casts and computed tomography data.

Authors:  Shingo Hara; Masaharu Mitsugi; Takahiro Kanno; Yukihiro Tatemoto
Journal:  Ann Maxillofac Surg       Date:  2014-01

6.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

7.  Augmented reality for dental implantology: a pilot clinical report of two cases.

Authors:  Gerardo Pellegrino; Carlo Mangano; Roberto Mangano; Agnese Ferri; Valerio Taraschi; Claudio Marchetti
Journal:  BMC Oral Health       Date:  2019-07-19       Impact factor: 2.757

Review 8.  Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance.

Authors:  Emitis Natali Naeini; Mandana Atashkadeh; Hugo De Bruyn; Jan D'Haese
Journal:  Clin Implant Dent Relat Res       Date:  2020-05-13       Impact factor: 3.932

9.  Comparison of Implant Placement Accuracy in Healed and Fresh Extraction Sockets between Static and Dynamic Computer-Assisted Implant Surgery Navigation Systems: A Model-Based Evaluation.

Authors:  Miaozhen Wang; Xiaohui Rausch-Fan; Yalin Zhan; Huidan Shen; Feng Liu
Journal:  Materials (Basel)       Date:  2022-04-11       Impact factor: 3.748

10.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study.

Authors:  Takeshi Toyoshima; Hideaki Tanaka; Masanori Sasaki; Eiji Ichimaru; Yasushi Naito; Yasuyuki Matsushita; Kiyoshi Koyano; Seiji Nakamura
Journal:  Clin Exp Dent Res       Date:  2015-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.