A comparative contrast-detail study of five medical displays.

Ehsan Samei1, Nicole T Ranger, David M Delong.   

Abstract

The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p <0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.

Entities:  

Mesh:

Year:  2008        PMID: 18491530     DOI: 10.1118/1.2868780

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

Authors:  Patrick Mc Laughlin; Siobhan O Neill; Noel Fanning; Anne Marie Mc Garrigle; Owen J O Connor; Gerry Wyse; Michael M Maher
Journal:  Emerg Radiol       Date:  2011-12-16

2.  Effect of display type, DICOM calibration and room illuminance in bitewing radiographs.

Authors:  Soili Kallio-Pulkkinen; Sisko Huumonen; Marianne Haapea; Esa Liukkonen; Annina Sipola; Osmo Tervonen; Miika T Nieminen
Journal:  Dentomaxillofac Radiol       Date:  2015-08-03       Impact factor: 2.419

3.  Effect of display type and room illuminance in chest radiographs.

Authors:  Esa Liukkonen; Airi Jartti; Marianne Haapea; Heljä Oikarinen; Lauri Ahvenjärvi; Seija Mattila; Terhi Nevala; Kari Palosaari; Marja Perhomaa; Miika T Nieminen
Journal:  Eur Radiol       Date:  2015-12-10       Impact factor: 5.315

4.  Technical and radiological image quality comparison of different liquid crystal displays for radiology.

Authors:  Francina Em Dams; K Y Esther Leung; Pieter Hm van der Valk; Marc Cjm Kock; Jeroen Bosman; Sjoerd P Niehof
Journal:  Med Devices (Auckl)       Date:  2014-10-31