Literature DB >> 18488236

Patella retention versus replacement in total knee arthroplasty; functional and clinimetric aspects.

Wouter L W van Hemert1, Rachel Senden, Bernd Grimm, Arnold D M Kester, Matthijs J A van der Linde, Ide C Heyligers.   

Abstract

INTRODUCTION: Whether to resurface the patella or not in total knee arthroplasty still remains undecided. Classical scores and questionnaires might not be responsive or demanding enough. This study used two accelerometer based systems to study the hypothesis whether performance based tests are able to detect a difference in patients with or without a resurfaced patella.
METHOD: In this retrospective study 53 patients were included and divided into a resurfaced group (n = 31) and a non-resurfaced group (n = 22). Both groups were matched on age and longevity of follow up. Patients were clinically assessed using the Knee Society Score (KSS) at various time points. At final follow up patients were also assessed once using the Dynaport Knee Test and the Minimod Gait Test.
RESULTS: The Dynaport Knee Test showed a significant functional advantage for patients with a resurfaced patella [44 vs. 39.7 (P = 0.042)], whereas KSS and The Minimod were not significant (P values ranging from 0.07 to 0.75). Similar to other reports in literature, using the KSS, it was not possible to identify significant difference between patella resurfacing or retaining in total knee arthroplasty, however using a performance based test it was possible to determine significant difference. The found advantage of patella resurfacing may be less due to pain relief but due to a functional benefit during demanding motion tasks. This finding indicates that current measurement tools may not be accurate or specific enough to detect this difference. Therefore, we recommend complementing the classic evaluation tools with an objective functional test, when conducting a randomized trial to answer the indecision whether to resurface the patella or not.

Entities:  

Mesh:

Year:  2008        PMID: 18488236     DOI: 10.1007/s00402-008-0640-8

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  10 in total

Review 1.  Patellar denervation with electrocautery in total knee arthroplasty without patellar resurfacing: a meta-analysis.

Authors:  Tao Cheng; Chen Zhu; Yongyuan Guo; Sifeng Shi; Desheng Chen; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-07       Impact factor: 4.342

2.  Predictors for secondary patellar resurfacing after primary total knee arthroplasty using a "patella-friendly" total knee arthroplasty system.

Authors:  Philip P Roessler; Randa Moussa; Cornelius Jacobs; Karl F Schüttler; Thomas Stein; Frank A Schildberg; Dieter C Wirtz
Journal:  Int Orthop       Date:  2018-08-01       Impact factor: 3.075

3.  A dutch survey on circumpatellar electrocautery in total knee arthroplasty.

Authors:  Hans-Peter W van Jonbergen; Alexander F W Barnaart; Cees C P M Verheyen
Journal:  Open Orthop J       Date:  2010-06-22

4.  Early functional outcome after subvastus or parapatellar approach in knee arthroplasty is comparable.

Authors:  Wouter L W van Hemert; Rachel Senden; Bernd Grimm; Matthijs J A van der Linde; Arno Lataster; Ide C Heyligers
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10-17       Impact factor: 4.342

Review 5.  Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis-A Scoping Review.

Authors:  Dylan Kobsar; Zaryan Masood; Heba Khan; Noha Khalil; Marium Yossri Kiwan; Sarah Ridd; Matthew Tobis
Journal:  Sensors (Basel)       Date:  2020-12-13       Impact factor: 3.576

6.  Isolated effects of patellar resurfacing in total knee arthroplasty and their relation to native patellar geometry.

Authors:  Adrian Sauer; Christoph Thorwaechter; Ingrid Dupraz; Allan Maas; Arnd Steinbrueck; Thomas M Grupp; Matthias Woiczinski
Journal:  Sci Rep       Date:  2022-07-28       Impact factor: 4.996

7.  Early outcomes of patella resurfacing in total knee arthroplasty.

Authors:  Warren J Clements; Lisa Miller; Sarah L Whitehouse; Stephen E Graves; Philip Ryan; Ross W Crawford
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Comparison of Clinical Results between Patellar Resurfacing and Non-resurfacing in Total Knee Arthroplasty: A Short Term Evaluation.

Authors:  Mohammad H Kaseb; Mohammad N Tahmasebi; Sm Javad Mortazavi; Mohammad R Sobhan; Mohammad H Nabian
Journal:  Arch Bone Jt Surg       Date:  2018-03

9.  Patellar resurfacing in total knee arthroplasty: functional outcome differs with different outcome scores: A randomized, double-blind study of 129 knees with 3 years of follow-up.

Authors:  Eirik Aunan; Grethe Næss; John Clarke-Jenssen; Leiv Sandvik; Thomas Johan Kibsgård
Journal:  Acta Orthop       Date:  2015-11-05       Impact factor: 3.717

10.  Current clinical utilisation of wearable motion sensors for the assessment of outcome following knee arthroplasty: a scoping review.

Authors:  Scott R Small; Garrett S Bullock; Sara Khalid; Karen Barker; Marialena Trivella; Andrew James Price
Journal:  BMJ Open       Date:  2019-12-29       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.