Tricuspid valve repair using the proportion between segments of normal tricuspid annulus as a parameter for annuloplasty.

Fernando Antoniali1, Domingo Marcolino Braile, Glória Maria Braga Potério, Gustavo Calado de Aguiar Ribeiro, Cledicyon Eloy da Costa, Maurício Marson Lopes.   

Abstract

OBJECTIVE: To determine the proportion between the segments of the normal human tricuspid valve (TV) annulus and its use as a parameter for ring annuloplasty "in vitro" and "in vivo".
METHODS: Digital images of the tricuspid ring of 30 human cadaveric hearts, without fixation and without tricuspid regurgitation (TR), were analyzed and the proportion between the antero-posterior and septal segments was determined. This proportion was used for TV annuloplasty with bovine pericardium (BP) flexible rings on 15 hearts from adult cadavers with TR and ring dilatation. The same proportion and technique were used for TV repair on 11 patients with functional TR. Preoperatively, seven patients had severe and four moderate TR; five patients were class IV and six class III (NYHA).
RESULTS: The mean ratio between the antero-posterior and septal segments was 2.43+/-0.212 in the 30 hearts without TR. The mean size of the BP flexible ring used for "in vitro" surgical procedure was 71.5+/-5.2 mm, median 70 mm, and there was no TR after that in all 15 hearts. The mean size of the orthesis used on the patients was 73.4+/-6.5 mm, median 72 mm. There was 1 hospital death. Six months after surgery, 7 patients had no TR and 3 had mild TR; 6 patients were in NYHA class I, 3 in class II and 1 in class III.
CONCLUSION: The use of the ratio 2.43:1 between the anterior-posterior and septal segments as a parameter in tricuspid valve annuloplasty with a bovine pericardium flexible ring leads to satisfactory results.

Entities:  

Mesh:

Year:  2007        PMID: 18488105     DOI: 10.1590/s0102-76382007000400004

Source DB:  PubMed          Journal:  Rev Bras Cir Cardiovasc


  1 in total

1.  New ring annuloplasty for extremely dilated tricuspid valve annulus: plication to physiologic septal segment size and over-reduction of posterior segment.

Authors:  Haruhiko Kondoh; Shinichi Hatsuoka; Hideo Shintani
Journal:  Tex Heart Inst J       Date:  2009