Effects of light exposure time on composite resin hardness after root reinforcement using translucent fibre post.

Cleonice da Silveira Teixeira1, Yara C Silva-Sousa, Manoel Damião de Sousa-Neto.   

Abstract

OBJECTIVES: The purpose of this in vitro study was to evaluate the Vickers hardness (VHN) of a Light Core (Bisco) composite resin after root reinforcement, according to the light exposure time, region of intracanal reinforcement and lateral distance from the light-transmitting fibre post.
METHODS: Forty-five 17-mm long roots were used. Twenty-four hours after obturation, the root canals were emptied to a depth of 12 mm and the root dentine was artificially flared to produce a 1mm space between the fibre post and the canal walls. The roots were bulk restored with the composite resin, which was photoactivated through the post for 40s (G1, control), 80 s (G2) or 120 s (G3). Twenty-four hours after post-cementation, the specimens were sectioned transversely into three slices at depths of 2, 6 and 10mm, corresponding to the coronal, middle and apical regions of the reinforced root. Composite VHN was measured as the average of three indentations (100g/15 s) in each region at lateral distances of 50, 200 and 350 microm from the cement/post-interface.
RESULTS: Three-way analysis of variance (alpha=0.05) indicated that the factors time, region and distance influenced the hardness and that the interaction timexregion was statistically significant (p=0.0193). Tukey's test showed that the mean VHN values for G1 (76.37+/-8.58) and G2 (74.89+/-6.28) differed significantly from that for G3 (79.55+/-5.18).
CONCLUSIONS: Composite resin hardness was significantly lower in deeper regions of root reinforcement and in lateral areas distant from the post. Overall, a light exposure time of 120 s provided higher composite hardness than the shorter times (40 and 80s).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18485559     DOI: 10.1016/j.jdent.2008.03.015

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  Comparison of two observational methods, scanning electron and confocal laser scanning microscopies, in the adhesive interface analysis of endodontic sealers to root dentine.

Authors:  Maybell Tedesco; Marcelo Carvalho Chain; Eduardo Antunes Bortoluzzi; Lucas da Fonseca Roberti Garcia; Ana Maria Hecke Alves; Cleonice Silveira Teixeira
Journal:  Clin Oral Investig       Date:  2018-01-17       Impact factor: 3.573

2.  Application of a Novel Modification of the Microbond Test for Evaluation of Adhesive Bond Strength Between Fiber Posts and Dual-Cure Dental Resin Cement.

Authors:  Aleksandra Maletin; Dubravka Markovic; Isidora Neskovic; Bojana Ramic; Tanja Veljovic; Ivan Ristic
Journal:  Med Sci Monit       Date:  2019-05-08

3.  Effect of etch-and-rinse and self-etching adhesive systems on hardness uniformity of resin cements after glass fiber post cementation.

Authors:  Fernanda Zander Grande da Cruz; Christiana Zander Grande; Douglas Augusto Roderjan; César Augusto Galvão Arrais; Adriana Postiglione Bührer Samra; Abraham Lincoln Calixto
Journal:  Eur J Dent       Date:  2012-07

4.  Evaluation of light transmission through different esthetic posts and its influence on the degree of polymerization of a dual cure resin cement.

Authors:  Sonali Taneja; Manju Kumari; Anupama Gupta
Journal:  J Conserv Dent       Date:  2013-01
  4 in total