Literature DB >> 18474770

Dynamic distribution of artificial tears on the ocular surface.

Jianhua Wang1, Peter Simmons, James Aquavella, Joseph Vehige, Jayachandra Palakuru, Suk Chung, Changyong Feng.   

Abstract

OBJECTIVE: To study the effects of artificial tear viscosity on tear film thickness, upper and lower tear menisci, and tear volume using optical coherence tomography.
METHODS: The central tear film and tear menisci before and immediately after the instillation of different artificial tears were imaged in 40 eyes of 20 healthy individuals. Carboxymethylcellulose sodium, 1.0% (viscosity, 70 cP), propylene glycol, 0.3%, and polyethylene glycol, 0.4% (10 cP), carboxymethylcellulose, 0.5% (3 cP), and isotonic sodium chloride solution (1 cP) were tested on 2 consecutive days. All measurements, including tear film thickness, the height, radius, and area of the tear meniscus, and the estimated tear volume, were obtained at 0, 5, 20, 40, and 60 minutes after instillation.
RESULTS: At instillation, all artificial tears and isotonic sodium chloride solution caused an increase in all tear variables (P < .001). Tear film thickness remained significantly elevated for all drops at 5 minutes (P < .001) and returned to baseline at 20 minutes. Other variables returned to baseline at 5 minutes. Comparing the different drops, tear film thickness and lower meniscus variables at instillation were increased with the more viscous drops (P < .05).
CONCLUSION: Optical coherence tomography demonstrated that all tear preparations, including isotonic sodium chloride solution, increased tear film thickness for at least 5 minutes and other variables immediately after instillation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18474770     DOI: 10.1001/archopht.126.5.619

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  6 in total

Review 1.  The international workshop on meibomian gland dysfunction: report of the subcommittee on management and treatment of meibomian gland dysfunction.

Authors:  Gerd Geerling; Joseph Tauber; Christophe Baudouin; Eiki Goto; Yukihiro Matsumoto; Terrence O'Brien; Maurizio Rolando; Kazuo Tsubota; Kelly K Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

2.  Reduced tear meniscus dynamics in dry eye patients with aqueous tear deficiency.

Authors:  Yimin Yuan; Jianhua Wang; Qi Chen; Aizhu Tao; Meixiao Shen; Mohamed Abou Shousha
Journal:  Am J Ophthalmol       Date:  2010-04-08       Impact factor: 5.258

3.  The relationship of tear osmolarity with tear meniscus curvature and contact angles in healthy subjects: anterior segment optical coherence tomography study.

Authors:  Volkan Yeter; Nurullah Koçak; Merve Kalyoncu; Ertuğrul Can; Nurşen Arıtürk
Journal:  Int Ophthalmol       Date:  2021-09-29       Impact factor: 2.031

4.  Automatic dynamic tear meniscus measurement in optical coherence tomography.

Authors:  Maciej M Bartuzel; Dorota H Szczesna-Iskander; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2014-07-23       Impact factor: 3.732

5.  Fourier-domain optical coherence tomography for monitoring the lower tear meniscus in dry eye after acupuncture treatment.

Authors:  Tong Lin; Lan Gong; Xiaoxu Liu; Xiaopeng Ma
Journal:  Evid Based Complement Alternat Med       Date:  2015-02-18       Impact factor: 2.629

6.  Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment.

Authors:  Jianhua Wang; Lele Cui; Meixiao Shen; Victor L Perez; Michael R Wang
Journal:  Clin Ophthalmol       Date:  2012-06-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.