Literature DB >> 18470995

General concept of high-performance amperometric detector for microfluidic (bio)analytical chips.

Christian Amatore1, Nicolas Da Mota, Catherine Sella, Laurent Thouin.   

Abstract

In this work, we established theoretically that amperometric detector arrays consisting of a series of parallel band microelectrodes placed on the wall of a microchannel may offer excellent analytical detection performances when implemented onto microfluidic (bio)analytical devices after the separative stages. In combination with the concentration imprinting strategies reported in a previous work, these exceptional performances may be extended to nonelectroactive or poorly diffusing analytes. Using an array of electrodes instead of a large single band allows the whole core of the channel to be probed though keeping an excellent time resolution. Thus, analytes with close retention times may be characterized individually with a resolution which eventually outpaces that of spectroscopic detections. Such important advantages may be obtained only through a complete understanding of the complex coupling between diffusional and convective transport of molecules in microfluidic solutions near an electrochemical detector. As a consequence, the conditions underlying the theoretical data presented in this work have been selected after optimizing procedures rooted on previous theoretical analyses. They will be fully disclosed in a series of further works that will also establish the experimental performances of such amperometric detectors and validate the present concept.

Mesh:

Year:  2008        PMID: 18470995     DOI: 10.1021/ac800227t

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.

Authors:  Alicia S Johnson; Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-07       Impact factor: 2.896

2.  Use of a Carbon-ink Microelectrode Array for Signal Enhancement in Microchip Electrophoresis with Electrochemical Detection.

Authors:  Laura C Mecker; Laura A Filla; R Scott Martin
Journal:  Electroanalysis       Date:  2010-10-01       Impact factor: 3.223

Review 3.  Use of epoxy-embedded electrodes to integrate electrochemical detection with microchip-based analysis systems.

Authors:  Asmira Selimovic; Alicia S Johnson; István Z Kiss; R Scott Martin
Journal:  Electrophoresis       Date:  2011-03-17       Impact factor: 3.535

4.  Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement.

Authors:  Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2013-07       Impact factor: 3.535

5.  Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection.

Authors:  Nongnoot Wongkaew; Peng He; Vanessa Kurth; Werasak Surareungchai; Antje J Baeumner
Journal:  Anal Bioanal Chem       Date:  2013-05-17       Impact factor: 4.142

6.  Decoding Network Structure in On-Chip Integrated Flow Cells with Synchronization of Electrochemical Oscillators.

Authors:  Yanxin Jia; István Z Kiss
Journal:  Sci Rep       Date:  2017-04-07       Impact factor: 4.379

7.  Electrochemical Generation and Detection of Transient Concentration Gradients in Microfluidic Channels. Theoretical and Experimental Investigations.

Authors:  Thomas Abadie; Catherine Sella; Pierre Perrodin; Laurent Thouin
Journal:  Front Chem       Date:  2019-10-24       Impact factor: 5.221

8.  Release and Detection of microRNA by Combining Magnetic Hyperthermia and Electrochemistry Modules on a Microfluidic Chip.

Authors:  Marie-Charlotte Horny; Vincent Dupuis; Jean-Michel Siaugue; Jean Gamby
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.