Literature DB >> 18470684

Fully supported open stent grafting applied with a Matsui-Kitamura (MK) stent in treatment of distal arch aneurysm.

Hirofumi Midorikawa1, Megumu Kanno, Kazunori Ishikawa.   

Abstract

OBJECTIVE: Our purpose was to examine the use of fully supported open stent grafting (OSG) with a Matsui-Kitamura (MK) stent for treatment of distal arch aneurysm (DAA).
METHODS: Surgery was performed using a newly developed device in seven DAA patients (six men and one woman) from 58 to 86 years of age (mean, 73 years old) from August 2005 to June 2007. The aorta was transected at the arch between bracheocephalic artery and left subclavian artery under circulatory arrest with total cardiopulmonary bypass and selective cerebral perfusion; then the stent grafting (SG) system was inserted and positioned with a 14 Fr. pusher. The SG and a transected edge were then sutured and anastomosed with the arch graft. The surgery was completed by constructing three cerebral branches.
RESULTS: The mean SG diameter and length were 34.6 mm (range, 32-38 mm) and 150 mm (120-200 mm), respectively. The mean time of circulatory arrest time and surgery were 41 min (35-55 min) and 358 min (269-450 min), respectively. Simultaneous mitral valve replacement was performed in one patient. All surgeries were completed successfully, and complete thrombosis of the aneurysm was obtained. Paraparesis and respiratory failure occurred in one patient each, and one patient died of brainstem infarction 1 month after surgery.
CONCLUSION: These initial results suggest that the OSG method is a useful surgical procedure for the treatment of DAA.

Entities:  

Mesh:

Year:  2008        PMID: 18470684     DOI: 10.1007/s11748-007-0223-6

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  16 in total

1.  Endovascular stent-graft repair with a flexible stent-graft and a simple applicator prepared from a syringe.

Authors:  Y Moriyama; Y Iguro; G Yotsumoto; S Watanabe; H Yamamoto
Journal:  J Thorac Cardiovasc Surg       Date:  2000-03       Impact factor: 5.209

2.  New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft.

Authors:  M Kato; K Ohnishi; M Kaneko; T Ueda; D Kishi; T Mizushima; H Matsuda
Journal:  Circulation       Date:  1996-11-01       Impact factor: 29.690

3.  Repair of the thoracic aorta by transaortic stent grafting (open stenting).

Authors:  Naomichi Uchida; Hiroshi Ishihara; Mitsuru Sakashita; Mikihiro Kanou; Tatsuaki Sumiyoshi
Journal:  Ann Thorac Surg       Date:  2002-02       Impact factor: 4.330

4.  Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up.

Authors:  R Greenberg; T Resch; U Nyman; M Lindh; J Brunkwall; P Brunkwall; M Malina; B Koul; B Lindblad; K Ivancev
Journal:  J Vasc Surg       Date:  2000-01       Impact factor: 4.268

5.  Stent grafting technique using Matsui-Kitamura (MK) stent for patients with aortic arch aneurysm.

Authors:  Junetsu Akasaka; Koichi Tabayashi; Yoshikatsu Saiki; Katsuhiko Oda; Kiichiro Kumagai; Atsushi Iguchi
Journal:  Eur J Cardiothorac Surg       Date:  2005-04       Impact factor: 4.191

6.  Clinical results of open stent grafting applied using an improved endotracheal tube in the treatment of high-risk patients with distal arch aneurysms.

Authors:  Hirofumi Midorikawa; Tomohiro Ogawa; Kouichi Satou; Shunichi Hoshino
Journal:  J Artif Organs       Date:  2004       Impact factor: 1.731

7.  The results of total arch graft implantation with open stent-graft placement for type A aortic dissection.

Authors:  Masaaki Kato; Toru Kuratani; Mitsunori Kaneko; Shunei Kyo; Kenji Ohnishi
Journal:  J Thorac Cardiovasc Surg       Date:  2002-09       Impact factor: 5.209

8.  Tactics and techniques of aortic arch replacement.

Authors:  H G Borst; B Bühner; M Jurmann
Journal:  J Card Surg       Date:  1994-09       Impact factor: 1.620

9.  Transaortic stented graft implantation for aortic arch aneurysm. Its benefits and risk.

Authors:  Tomohiro Mizuno; Masaaki Toyama; Noriyuki Tabuchi; Makoto Sunamori
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2003-02

10.  Open stent-grafting for aortic arch aneurysm is associated with increased risk of paraplegia.

Authors:  Takeshi Miyairi; Yutaka Kotsuka; Masahiko Ezure; Minoru Ono; Tetsuro Morota; Hiroshi Kubota; Ko Shibata; Katsuhito Ueno; Shinichi Takamoto
Journal:  Ann Thorac Surg       Date:  2002-07       Impact factor: 4.330

View more
  3 in total

1.  Long-term results of open stent-grafting using a Matsui-Kitamura stent to treat thoracic aortic aneurysm.

Authors:  Hirofumi Midorikawa; Megumu Kanno; Takashi Takano; Kouyu Watanabe; Kyohei Ueno; Takashi Ono; Kouichi Satou
Journal:  Ann Thorac Cardiovasc Surg       Date:  2014-06-03       Impact factor: 1.520

Review 2.  Aortic arch replacement for degenerative aneurysms: advances during the last decade.

Authors:  Norihiko Shiiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-10-20

Review 3.  Open stent grafting for complex diseases of the thoracic aorta: clinical utility.

Authors:  Naomichi Uchida
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-09-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.