Corrosion behaviour of Ti-15Mo alloy for dental implant applications.

Satendra Kumar1, T S N Sankara Narayanan.   

Abstract

The corrosion behaviour of Ti-15Mo alloy in 0.15M NaCl solution containing varying concentrations of fluoride ions (190, 570, 1140 and 9500 ppm) is evaluated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and chronoamperometric/current-time transient (CTT) studies to ascertain its suitability for dental implant applications. The study reveals that there is a strong dependence of the corrosion resistance of Ti-15Mo alloy on the concentration of fluoride ions in the electrolyte medium. Increase in fluoride ion concentration from 0 to 9500 ppm shifts the corrosion potential (E(corr)) from -275 to -457 mV vs. SCE, increases the corrosion current density (i(corr)) from 0.31 to 2.30 microA/cm(2), the passive current density (i(pass)) from 0.07 to 7.32 mA/cm(2) and the double-layer capacitance (C(dl)) from 9.63 x 10(-5) to 1.79 x 10(-4)F and reduces the charge transfer resistance (R(ct)) from 6.58 x 10(4) to 6.64 x 10(3)Omega cm(2). In spite of the active dissolution, the Ti-15Mo alloy exhibit passivity at anodic potentials at all concentrations of the fluoride ions studied. In dental implants since the exposure of the alloy will be limited only to its 'neck', the amount of Mo ions released from Ti-15Mo alloy is not likely to have an adverse and hence, in terms of biocompatibility this alloy seems to be acceptable for dental implant applications. The results of the study suggest that Ti-15Mo alloy can be a suitable alternative for dental implant applications.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18468762     DOI: 10.1016/j.jdent.2008.03.007

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  6 in total

1.  Electrochemical behavior and corrosion resistance of Ti-15Mo alloy in naturally-aerated solutions, containing chloride and fluoride ions.

Authors:  A V Rodrigues; N T C Oliveira; M L dos Santos; A C Guastaldi
Journal:  J Mater Sci Mater Med       Date:  2015-01-11       Impact factor: 3.896

2.  Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.

Authors:  F Rosalbino; S Delsante; G Borzone; G Scavino
Journal:  J Mater Sci Mater Med       Date:  2012-03-02       Impact factor: 3.896

3.  Biomimetic calcium phosphate coating on Ti-7.5Mo alloy for dental application.

Authors:  A L A Escada; J P B Machado; S G Schneider; M C R Alves Rezende; A P R Alves Claro
Journal:  J Mater Sci Mater Med       Date:  2011-09-10       Impact factor: 3.896

4.  Corrosion behaviour of β-Ti20Mo alloy in artificial saliva.

Authors:  Daniel Mareci; Romeu Chelariu; Ioan Dan; Doina-Margareta Gordin; Thierry Gloriant
Journal:  J Mater Sci Mater Med       Date:  2010-08-15       Impact factor: 3.896

Review 5.  Mixed oxide nanotubes in nanomedicine: A dead-end or a bridge to the future?

Authors:  Masoud Sarraf; Bahman Nasiri-Tabrizi; Chai Hong Yeong; Hamid Reza Madaah Hosseini; Saeed Saber-Samandari; Wan Jefrey Basirun; Takuya Tsuzuki
Journal:  Ceram Int       Date:  2020-09-24       Impact factor: 4.527

6.  Ti-15Mo Alloy Decreases the Stress Concentration in Mandibular Angle Fracture Internal Fixation Hardware.

Authors:  F P S Guastaldi; A P Martini; E P Rocha; E Hochuli-Vieira; A C Guastaldi
Journal:  J Maxillofac Oral Surg       Date:  2019-06-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.