Literature DB >> 18468441

Detection of gait events using an F-Scan in-shoe pressure measurement system.

Paola Catalfamo1, David Moser, Salim Ghoussayni, David Ewins.   

Abstract

A portable system capable of accurate detection of initial contact (IC) and foot off (FO) without adding encumbrance to the subject would be extremely useful in many gait analysis applications. Force platforms represent the gold standard method for determining these events and other methods including foot switches and kinematic data have also been proposed. These approaches, however, present limitations in terms of the number of steps that can be analysed per trial, the portability for outdoor measurements or the information needed beforehand. The purpose of this study was to evaluate the F-Scan((R)) Mobile pressure measurement system when detecting IC and FO. Two methods were used, one was the force detection (FD) in-built algorithm used by F-Scan software and a new area detection (AD) method using the loaded area during the gait cycle. Both methods were tested in ten healthy adults and compared with the detection provided by a kinetic detection (KT) algorithm. The absolute mean differences between KT and FD were (mean+/-standard deviation) 42+/-11 ms for IC and 37+/-11 ms for FO. The absolute mean differences between KT and AD were 22+/-9 ms for IC and 10+/-4 ms for FO. The AD method remained closer to KT detection for all subjects providing sufficiently accurate detection of both events and presenting advantages in terms of portability, number of steps analysed per trial and practicality as to make it a system of choice for gait event detection.

Entities:  

Mesh:

Year:  2008        PMID: 18468441     DOI: 10.1016/j.gaitpost.2008.01.019

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  22 in total

1.  An adaptive gyroscope-based algorithm for temporal gait analysis.

Authors:  Barry R Greene; Denise McGrath; Ross O'Neill; Karol J O'Donovan; Adrian Burns; Brian Caulfield
Journal:  Med Biol Eng Comput       Date:  2010-11-02       Impact factor: 2.602

2.  Gait Cycle Validation and Segmentation Using Inertial Sensors.

Authors:  G V Prateek; Pietro Mazzoni; Gammon M Earhart; Arye Nehorai
Journal:  IEEE Trans Biomed Eng       Date:  2019-11-25       Impact factor: 4.538

3.  Foot contact forces can be used to personalize a wearable robot during human walking.

Authors:  Michael Jacobson; Prakyath Kantharaju; Hyeongkeun Jeong; Jae-Kwan Ryu; Jung-Jae Park; Hyun-Joon Chung; Myunghee Kim
Journal:  Sci Rep       Date:  2022-06-29       Impact factor: 4.996

4.  Gait event detection on level ground and incline walking using a rate gyroscope.

Authors:  Paola Catalfamo; Salim Ghoussayni; David Ewins
Journal:  Sensors (Basel)       Date:  2010-06-04       Impact factor: 3.576

5.  The effect of ankle joint muscle strengthening training and static muscle stretching training on stroke patients' C.o.p sway amplitude.

Authors:  Tae Ho Kim; Joo Soo Yoon; Jin Hwan Lee
Journal:  J Phys Ther Sci       Date:  2014-01-08

6.  A modular sensorized mat for monitoring infant posture.

Authors:  Marco Donati; Francesca Cecchi; Filippo Bonaccorso; Marco Branciforte; Paolo Dario; Nicola Vitiello
Journal:  Sensors (Basel)       Date:  2013-12-31       Impact factor: 3.576

7.  Gait event detection during stair walking using a rate gyroscope.

Authors:  Paola Catalfamo Formento; Ruben Acevedo; Salim Ghoussayni; David Ewins
Journal:  Sensors (Basel)       Date:  2014-03-19       Impact factor: 3.576

8.  The configuration of plantar pressure sensing cells for wearable measurement of COP coordinates.

Authors:  Dian Wang; Ping Cai; Zhiyong Mao
Journal:  Biomed Eng Online       Date:  2016-10-26       Impact factor: 2.819

Review 9.  Gait Partitioning Methods: A Systematic Review.

Authors:  Juri Taborri; Eduardo Palermo; Stefano Rossi; Paolo Cappa
Journal:  Sensors (Basel)       Date:  2016-01-06       Impact factor: 3.576

Review 10.  Sensor Fusion and Smart Sensor in Sports and Biomedical Applications.

Authors:  José Jair Alves Mendes; Mário Elias Marinho Vieira; Marcelo Bissi Pires; Sergio Luiz Stevan
Journal:  Sensors (Basel)       Date:  2016-09-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.