Literature DB >> 18467785

Effects of resilient denture liner in mandibular complete denture on the satisfaction ratings of patients at the first appointment following denture delivery.

Suguru Kimoto1, Katsuhiko Kimoto, Atsuko Gunji, Yasuhiko Kawai, Hiroshi Murakami, Kinya Tanaka, Kazuyoshi Syu, Hiromichi Aoki, Masaaki Tani, Minoru Toyoda, Kihei Kobayashi.   

Abstract

PURPOSE: The purpose of this study was to investigate whether edentulous patients with a permanent acrylic resilient liner denture (RLD) in mandibles exhibit significant improvements in their satisfaction ratings at the first appointment following the delivery of RLD dentures when compared to those with conventional heat-activated acrylic resin dentures (ARD) in mandibles.
METHODS: Seventy-four subjects were randomly allocated into RLD and ARD groups by a random permuted block within the strata method after written informed consent. A parallel-randomized controlled clinical trial at two centers was conducted from April 2004 to July 2006. The outcomes were satisfaction ratings with a 100 mm visual analog scale (VAS) involving general satisfaction as well as satisfaction related to chewing, speaking, cleaning, stability, retention, comfort, and esthetics. The pain rating was also measured by the VAS. The outcomes were analyzed by Student t-test and Pearson's correlation coefficient.
RESULTS: A significant difference between the RLD and ARD group in the maxillary denture was only obtained in the satisfaction rating of speaking. A significant difference between the RLD and ARD groups for the mandibular dentures was obtained in every satisfaction rating. The pain rating of the RLD group was significantly lower than that of the ARD group. The satisfaction ratings of mandibular denture functions significantly correlated with ratings of comfort and pain.
CONCLUSION: Despite the limitation of a short-term observation, the mandibular satisfaction ratings were dramatically higher in RLD wearers than in ARD wearers.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18467785     DOI: 10.2186/jjps.52.160

Source DB:  PubMed          Journal:  Nihon Hotetsu Shika Gakkai Zasshi        ISSN: 0389-5386


  6 in total

1.  Creep and stress relaxation behavior of two soft denture liners.

Authors:  Alaa'a M Salloum
Journal:  J Indian Prosthodont Soc       Date:  2013-03-21

2.  Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures.

Authors:  Katayoun Sadr; Jahangir Alipour; Fateme Heidary
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-06-06

Review 3.  Long-Term Soft Denture Lining Materials.

Authors:  Grzegorz Chladek; Jarosław Żmudzki; Jacek Kasperski
Journal:  Materials (Basel)       Date:  2014-08-12       Impact factor: 3.623

4.  Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base.

Authors:  Farhang Mahboub; Fariba Salehsaber; Fereydoon Parnia; Vahedeh Gharekhani; Yousef Kananizadeh; Mahsa Taghizadeh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

5.  Effect of different mouthwashes on the shear bond strength and surface roughness of intraoral and heat-cured soft liners.

Authors:  Shima Ghasemi; Amir Reza Babaloo; Mahsa Taghizadeh; Yousef Kananizadeh; Mehrnaz Sheikholeslami
Journal:  Dent Res J (Isfahan)       Date:  2022-08-16

6.  Effect of Silver-Emitting Filler on Antimicrobial and Mechanical Properties of Soft Denture Lining Material.

Authors:  Ewa Jabłońska-Stencel; Wojciech Pakieła; Anna Mertas; Elżbieta Bobela; Jacek Kasperski; Grzegorz Chladek
Journal:  Materials (Basel)       Date:  2018-02-22       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.