Literature DB >> 18467299

Atrial vs. dual-chamber cardiac pacing in sinus node disease: a register-based cohort study.

C Michael Fored1, Fredrik Granath, Fredrik Gadler, Paul Blomqvist, Jenny Rynder, Cecilia Linde, Anders Ekbom, Mårten Rosenqvist.   

Abstract

AIMS: In patients with sinus node disease, dual-chamber pacing (DDD) possibly results in adverse effects on the ventricular function. We have compared the incidence of cardiovascular morbidity and mortality in patients with sinus node disease and with atrioventricular (AV) synchronous pacemakers, DDD vs. atrial pacing (AAI). METHODS AND
RESULTS: A nation-wide population-based cohort of 8777 patients with AAI- or DDD-mode pacemakers was followed during 12 years. The cohort was linked to national healthcare and census registers. Patients with DDD pacing and without any pre-implant admission for atrial fibrillation or flutter had an increased risk of post-implant fibrillation or flutter, in relation to corresponding AAA patients [hazard ratio (HR) = 1.30; 95% confidence interval (CI) 1.10-1.52]. A slight increase in the risk of any cardiovascular disease (HR = 1.07; CI, 1.00-1.15), and all-cause mortality (HR = 1.12; CI, 1.00-1.25), was seen among DDD patients, in relation to AAI patients, but there was no significant difference in the risk of ischaemic or unspecified stroke (HR = 1.14; CI, 0.94-1.37). Among DDD patients, the all-cause mortality did not differ from the general population [standardized mortality ratio (SMR) = 1.04; CI, 0.98-1.11]. Patients with AAI, however, had a decreased all-cause mortality risk (SMR = 0.89; CI, 0.82-0.97).
CONCLUSION: Our results support AAI as the preferred mode of pacing in patients with sinus node disease, and a normal AV node function.

Entities:  

Mesh:

Year:  2008        PMID: 18467299     DOI: 10.1093/europace/eun118

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  [Scientific results of the pacemaker register: possibilities and limits].

Authors:  U K H Wiegand; B Lemke; B Nowak
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-09

2.  [Maintenance of AAI(R) mode at the time of generator replacement].

Authors:  E Wunderlich; H Schindler; A Hetze; C Wunderlich
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-09

3.  Association of selected factors with long-term prognosis and mortality after dual-chamber pacemaker implant.

Authors:  Maciej Dębski; Mateusz Ulman; Andrzej Ząbek; Krzysztof Boczar; Kazimierz Haberka; Marcin Kuniewicz; Jacek Lelakowski; Barbara Małecka
Journal:  Cardiol J       Date:  2018-08-29       Impact factor: 2.737

4.  Long-term mortality outcomes according to the frequency of right ventricular pacing in veterans.

Authors:  Brent C Lampert; Hans J Moore; Richard L Amdur; Pamela E Karasik; Brian M Lewis; Steven N Singh; Ross D Fletcher
Journal:  Cardiol Res Pract       Date:  2010-05-05       Impact factor: 1.866

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.