Literature DB >> 18465947

Handheld forward-imaging needle endoscope for ophthalmic optical coherence tomography inspection.

Shuo Han1, Marinko V Sarunic, Jigang Wu, Mark Humayun, Changhuei Yang.   

Abstract

We report the narrowest to-date (21 gauge, 820-microm-diam) handheld forward-imaging optical coherence tomography (OCT) needle endoscope and demonstrate its feasibility for ophthalmic OCT inspection. The probe design is based on paired-angle-rotation scanning (PARS), which enables a linear B-scan pattern in front of the probe tip by using two counterrotating angle polished gradient-index (GRIN) lenses. Despite its small size, the probe can provide a numerical apertune (NA) of 0.22 and an experimental sensitivity of 92 dB at 0.5 frames. The feasibility of retinal imaging is tested on enucleated ex vivo porcine eyes, where structural features including remnant vitreous humor, retina, and choroid can be clearly distinguished. Due to its imaging quality comparable to a commercial OCT system and compatibility with the current ophthalmic surgery standard, the probe can potentially serve as a better alternative to traditional visual inspection by white light illumination during vitreoretinal surgery (e.g., vitrectomy).

Entities:  

Mesh:

Year:  2008        PMID: 18465947     DOI: 10.1117/1.2904664

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  32 in total

1.  Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers.

Authors:  Mohamed T El-Haddad; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2015-07-23       Impact factor: 3.732

2.  Miniature real-time intraoperative forward-imaging optical coherence tomography probe.

Authors:  Karen M Joos; Jin-Hui Shen
Journal:  Biomed Opt Express       Date:  2013-07-16       Impact factor: 3.732

3.  Design of a handheld optical coherence microscopy endoscope.

Authors:  Vrushali R Korde; Erica Liebmann; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

4.  Miniature forward-viewing common-path OCT probe for imaging the renal pelvis.

Authors:  Xiaoyong Fu; Dhruti Patel; Hui Zhu; Gregory MacLennan; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2015-03-06       Impact factor: 3.732

Review 5.  A comprehensive review of diagnostic imaging technologies to evaluate the retina and the optic disk.

Authors:  Asima Bajwa; Rabia Aman; Ashvini K Reddy
Journal:  Int Ophthalmol       Date:  2015-06-05       Impact factor: 2.031

6.  Real-time epidural anesthesia guidance using optical coherence tomography needle probe.

Authors:  Qinggong Tang; Chia-Pin Liang; Kyle Wu; Anthony Sandler; Yu Chen
Journal:  Quant Imaging Med Surg       Date:  2015-02

7.  Review of intraoperative optical coherence tomography: technology and applications [Invited].

Authors:  Oscar M Carrasco-Zevallos; Christian Viehland; Brenton Keller; Mark Draelos; Anthony N Kuo; Cynthia A Toth; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

8.  Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.

Authors:  Yuankai K Tao; Sunil K Srivastava; Justis P Ehlers
Journal:  Biomed Opt Express       Date:  2014-05-20       Impact factor: 3.732

9.  Investigation of gold-coated bare fiber probe for in situ intra-vitreous coherence domain optical imaging and sensing.

Authors:  J-H Han; I K Ilev; D-H Kim; C G Song; J U Kang
Journal:  Appl Phys B       Date:  2010-06-01       Impact factor: 2.070

10.  Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.

Authors:  Paul Hahn; Justin Migacz; Rachelle O'Donnell; Shelley Day; Annie Lee; Phoebe Lin; Robin Vann; Anthony Kuo; Sharon Fekrat; Prithvi Mruthyunjaya; Eric A Postel; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2013 Jul-Aug       Impact factor: 4.256

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.