Work of fracture of a composite resin: fracture-toughening mechanisms.

Carmen Baudin1, Raquel Osorio, Manuel Toledano, Salvador de Aza.   

Abstract

The aim of this work was to investigate those mechanical parameters able to describe the fracture behavior of dental composite resins. A commercially available fine-particle micro-hybrid resin composite was used. Classical parameters as Young's modulus, strength distribution, and critical stress intensity factor were considered. Strength values were determined using the diametrical compression of discs test and for the critical stress intensity factor both unstable and controlled fracture tests were used. Controlled fracture tests allowed determining the work of fracture. Microstructure was studied by optical and field emission scanning electron microscopy. The obtained properties have been Young's modulus, 17.7 +/- 0.6 GPa; Weibull modulus, m = 14 (upper and lower limits for 90% confidence: 17 and 10); characteristic strength 51 MPa (upper and lower limits for 90% confidence: 53 and 49 MPa); critical stress intensity factor in mode I, K(IC) = 1.3 +/- 0.1 and work of fracture, gamma(wof) = 8-9 J/m(2). Pores and bubbles formed during the packing of the composite were identified as critical defects in the tested specimens. Crack deflection and branching have been identified as toughening mechanisms. Classical mechanical parameters (Young's modulus, hardness...) are not able to efficiently predict the major clinical failure mode of composite resins by fatigue. Work of fracture analysis, which is dependant on microstructural parameters such as particle size and shape, have to be included when testing mechanical properties of dental composite resins in future research studies. 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18465813     DOI: 10.1002/jbm.a.32016

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  3 in total

Review 1.  Polymer-Based Direct Filling Materials.

Authors:  Carmem S Pfeifer
Journal:  Dent Clin North Am       Date:  2017-10

2.  Quantification of porosity in composite resins delivered by injectable syringes using X-ray microtomography.

Authors:  Bo Wold Nilsen; Mathieu Mouhat; Asbjørn Jokstad
Journal:  Biomater Investig Dent       Date:  2020-07-06

3.  3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation.

Authors:  İsmail Hakkı Uzun; Meral Arslan Malkoç; Ali Keleş; Ayşe Tuba Öğreten
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.