Comparison of higher-order aberrations after LASIK using disposable microkeratome 130 and 90 micron heads.

M Hosny1, M A Awadalla.   

Abstract

PURPOSE: To analyze and compare higher-order aberrations (HOAs) in cases of laser in situ keratomileusis (LASIK) flaps made using the Moria M2 disposable 130-micronm head with those made using the 90-micronm head.
METHODS: Consecutive prospective comparative clinical trial. Ninety-four consecutive eyes of 48 patients were enrolled in this study. They were divided into two equal groups of 47 eyes that underwent wavefront-guided LASIK using VISX CustomVue (VISX, Santa Clara, CA) system. Corneal flap was created using the disposable Moria M2 130 micronm in the first group and the 90 micronm head in the second one. All patients were followed up for 6 months. Wavefront aberrations were measured at baseline, 1 month, and 6 months after surgery using the WaveScan (VISX Inc.) aberrometer. Root mean square (RMS) of HOAs, coma, and spherical aberration (SA) values were analyzed and compared in the two groups.
RESULTS: At 6 months, values of RMS of HOAs, coma, and SA obtained from the 130-micronm head group were 0.32+/-0.10 micronm, 0.20+/-0.11 micronm, and 0.18+/-0.08 micronm, respectively. Values of RMS of HOAs, coma, and SA obtained from 90-micronm head group were 0.33+/-0.12 micronm, 0.19+/-0.10 micronm, and 0.15+/-0.08 micronm, respectively. Analyzing the data obtained revealed no statistically significant differences between the two groups. In each group, there was a significant decay of higher-order RMS and coma values from 1 month to 6 months.
CONCLUSIONS: HOAs following use of Moria M2 disposable 90 micronm head are similar to those arising following use of the 130 micronm.

Entities:  

Mesh:

Year:  2008        PMID: 18465711     DOI: 10.1177/112067210801800302

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  The association between femtosecond laser flap parameters and ocular aberrations after uncomplicated custom myopic LASIK.

Authors:  Christopher T Hood; Ronald R Krueger; Steven E Wilson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-04-09       Impact factor: 3.117

2.  [Wavefront analysis in ophthalmologic diagnostics].

Authors:  M J Sanchez; A Mannsfeld; A F M Borkenstein; A Ehmer; I-J Limberger; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.